background image

-3-

SPECIAL FEATURES

Daisy-Chain Capability

Using the auxiliary outlet on the control panel, you can link up to 3 units together. You can also

daisy-chain the machines when they are stacked vertically (limit of 2 units).

Multi-Positional

The air scrubber can be operated in the vertical position, as well as, when stacked vertically (up to 2

units). When storing, the machines can be stacked horizontally to save space.

Removable Intake Panel

The air scrubber is equipped with a removable panel on the intake side of the machine. The

removable panel is quite useful in remediation applications, so you can draw air out the room and

create more negative pressure. To use panel:

1.

Remove the panel.

2.

Install the machine outside the containment area to draw air out.

3.

Cut a hole in the containment plastic that is the size of the unit's inlet.

4.

Insert the inlet into plastic and seal the circumference tightly with duct tape.

KEY FEATURES

Vertical, upright
position

Air outlet

(dectable, 8")

Latches (2)

Inlet

(dectable, 12")

Removeable plastic

cover

Handle

Summary of Contents for AS-550

Page 1: ...1 Restoration Moisture Ventilation Owner s Manual AS 550 READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...e sure to note the serial number and date of purchase Serial Number Date of Purchase HOW IT WORKS When set to maximum airflow scrubbers pass through three types of filters pre filters activated carbon...

Page 3: ...ble Intake Panel The air scrubber is equipped with a removable panel on the intake side of the machine The removable panel is quite useful in remediation applications so you can draw air out the room...

Page 4: ...t There is a maximum amperage of 12 when the units are turned off a maximum of 9 amps when the units are turned on Other equipment can be plugged into the same outlet as the air scrubber as long as it...

Page 5: ...t will start cleaning the air Keep in mind that if you are working in a large area or one divided by walls you may need several air scrubbers to effectively clean the air Odor Control The air scrubber...

Page 6: ...ge the filter Make sure the unit is dry prior to installing clean filters When using the air scrubber for remediation purposes replace both filters at the same time and always clean machine in between...

Page 7: ...following 1 Customer must provide normal care and maintenance including but not limited to cleaning filters 2 Removal and re installation of unit is the sole responsibility of owner 3 If customer can...

Page 8: ...D LED K K K UV CN3 CN4 CN5 UV UV CN6 CN7 L N CAPACITANCE UV Germicidal Lamp BALLAST TIMER CHANGE HEPAFILTER Potentiometer RT Switch Socket Overload protection switch Black Red Brown Blue Green Black U...