Remove ceramic portion of sink (See
“Removing Old Seal”). Grasp copper
cone with fingers at the large end and
move back and forth. Be careful not to
deform it.
COPPER HEAT SINK
INSTALLATION
1. Clean off all sealant and foreign
material.
2. Clean out heat sink cavity in seal
plate.
3. Apply thin layer of non-hardening
Permatex on outer surface of heat
sink (part that fits into cavity,
Figure 12).
4. Using standard 7/8" socket, bolt,
and 1-3/8" washer pull heat sink into
cavity (See Figure 13).
5. Clean out any surplus Permatex
from insert cavity where new seal
will be located (Figure 14).
6. Follow steps 2 through 11 under
“Installing New Seal”.
PUMP REASSEMBLY
1. Install new O-Ring gasket on seal
plate (Figure 15, Key Nos. 5 and 3).
2. Pick up a small amount of liquid
soap on one finger and spread
evenly over O-Ring gasket for lubri-
cation during reassembly. Be care-
ful not to nick or tear O-Ring.
3. Replace motor onto pump body; be
sure rubber pad stays in place on
top of diffuser. Tighten four hex
nuts and lockwashers snugly
(35-45 inch-lbs. torque). Do not
overtighten.
4. Replace pressure switch tubing and
motor wiring.
5. Prime pump according to instruc-
tions; see Operation.
6. Check for leaks.
W
ipe a small amo
u
nt of
non-hardening Permatex onto
this s
u
rface.
7/8" SOCKET
BOLT
1-3/8" O.D.
WASHER
038 0893
Figure 12
Figure 13
Remove
Surplus
Permatex
Properly
Seated
039 0893
Figure 14
7/8" Socket
1
3
⁄
8
" O.D.
Washer
Remove
surplus
Permatex
Properly
seated
Bolt
Pump Brand
For Use With Kit No.:
FPP1520
FPP1521
Flotec
FP4001-08, FP4012-08
FP4022-08
Simer
3105P
3107P
Teel
4AT96, 4AT97
4AT98
Diamond
314071-01
301472
Craftsman
2805
–––
Seal and Gasket Kit
FPP1530
works with all models listed above.
INSTALLING NEW SEAL (continued)
3