EN
| User Manual
Annex with technical documentation
AKM 1-8
35
Evaluation tables for determination of the residual oil content
At 4 bar operating pressure
Duration
[h]
Number of fi rst-ever coloured scale units
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
4
1.00
1.95
2.90
3.85
4.90
5.95
6.75
7.50
4.5
0.90
1.75
2.55
3.40
4.35
5.10
6.10
6.80
5
0.80
1.55
2.35
3.10
3.90
4.70
5.50
6.20
5.5
0.75
1.40
2.15
2.80
3.55
4.25
5.00
5.80
6
0.70
1.30
1.95
2.60
3.30
3.85
4.60
5.10
6.5
0.65
1.20
1.80
2.35
3.00
3.60
4.25
4.80
7
0.60
1.10
1.70
2.25
2.75
3.30
3.85
4.50
8.5
0.50
0.95
1.40
1.85
2.30
2.75
3.25
3.65
10
0.40
0.80
1.18
1.55
1.95
2.30
2.70
3.10
12.5
0.31
0.70
1.00
1.30
1.55
1.85
2.20
2.50
16.5
0.24
0.50
0.70
1.00
1.25
1.40
1.65
1.90
25
0.155
0.310
0.500
0.700
0.800
1.000
1.100
1.300
33
0.120
0.240
0.380
0.500
0.620
0.750
0.850
1.000
50
0.075
0.155
0.230
0.310
0.400
0.500
0.600
0.700
56
0.065
0.135
0.210
0.280
0.350
0.420
0.500
0.600
63
0.058
0.125
0.185
0.250
0.305
0.355
0.420
0.500
72
0.050
0.095
0.160
0.195
0.270
0.310
0.380
0.420
84
0.040
0.090
0.140
0.185
0.225
0.280
0.310
0.370
100
0.036
0.075
0.118
0.155
0.195
0.230
0.275
0.310
125
0.030
0.059
0.090
0.125
0.155
0.185
0.230
0.250
166
0.020
0.048
0.064
0.090
0.118
0.135
0.155
0.185
250
0.012
0.030
0.048
0.059
0.075
0.090
0.095
0.125
500
0.005
0.012
0.020
0.030
0.036
0.048
0.055
0.059
1000
0.002
0.005
0.010
0.012
0.015
0.020
0.025
0.030
Table for the determination of the residual oil content in [ppm] at 4 bar operating pressure
Summary of Contents for Zander AKM 1
Page 2: ......
Page 4: ...EN User Manual 2 AKM 1 8 D3...
Page 42: ...EN User Manual 40 AKM 1 8 D3...
Page 43: ......