Start-up
AKM 1-8
19
Slowly open the compressed air inlet valve, installed by the owner, upstream of the adsor-
ber.
Open compressed air outlet line
Slowly open compressed air outlet valve!
Avoid sudden pressure build-up in any circumstance! If pressure builds up too
fast, this may cause damage to the adsorber. Therefore, the compressed air
inlet valve must always be opened quite slowly!
Slowly open the compressed air outlet valve installed by the owner. The pressure should
not drop below the operating pressure (if poss.). If necessary, keep the compressed air outlet
valve in a slightly open position until the compressed air system downstream of the adsorber
has fi lled up completely; only then should the valve be opened fully.
The adsorber has then be taken into operation within the compressed air system.
In the event of a fault
In the event of an emergency or if a safety-relevant disruption occurs (e.g. escaping com-
pressed air, defective component), immediately close and depressurise the respective system
section. Then proceed as follows:
Look up possible cause of the fault, and how to remedy the same, in the table on page
31
.
Remedy fault.
Repeat the start-up procedure.