EN
| User Manual
Annex with technical documentation
AKM 1-8
33
Technical data
Operating Range
Site Selection
frost-free indoor installation in a
non-hazardous environment
Ambient temperature
1,5 to 50 °C (34,7 to 122 °F)
Compressed air inlet temperature
25 to 50 °C (68 to 122 °F)
Max. operating overpressure
16 bar
e
Medium
Compressed air and gaseous nitrogen
Fluid group
2
Performance details
Type
Volumetric
fl ow¹
in m3/h
Nominal
2
pipe
size
Downstream
fi lter
Nominal
Pressure in
bar
e
Nominal
temperature
°C
AKM 1
8
1/4
AOP010AGMI 16
50
AKM 2
15
1/4
AOP010AGMI 16
50
AKM 3
25
1/4
AOP010AGMI 16
50
AKM 4
35
1/4
AOP010AGMI 16
50
AKM 6
56
1/2
AOP015CGMI 16
50
AKM 7
72
1/2
AOP015CGMI 16
50
AKM 8
86
3/4
AOP020DGFI 16
50
1
. m3/h relating to 1 bara and 20 °C, subsequently compressed to 7 bare, 35 °C Adsorber
Inlet temperature; relative humidity < 20 %.
2
In accordance with DIN ISO 228 (BSP-P); alternatively ANSI B 1.20.1 (NPT-F).
Purifying agent
Chamber 1
100 % Purifying agent activated carbon
Dimensions
Please heed to the dimensional drawings and the according table containing dimensions
and weight on page 39.