3.1.2.2. Water cooled motor
Typical values are given with a water inlet temperature of 25°C and a temperature
gradient Inlet-Outlet of 10°C. These references lead to a winding overheating of 95°C
corresponding to a winding temperature of 120°C. Recommendations regarding
condensation issues are given at § 3.5
It is possible to increase a little bit the Inlet temperature up to 45°C, but the torque
must be reduced. The following curves give an indicative of the derating versus the
speed for different temperature.
80%
82%
84%
86%
88%
90%
92%
94%
96%
98%
100%
0
100
200
300
400
500
600
D
e
rating
co
e
ff
ic
ie
n
t
wi
th
in
le
t
wat
e
r t
e
m
p
e
ratu
re
Speed (rpm)
Derating curve vs speed for TMW2xx at
nominal water flow (50%glycol)
Inlet25°C
Inlet 30°C
Inlet 35°C
Inlet 40°C
Inlet 45°C