Page 138
– Bulletin 100-50-9.1
Parameter
Description
Use
Display
LT Control Temperature Low Alarm
Threshold
Low alarm threshold for Low Temperature
operation (Dual Temp)
LT Control Temperature High Alarm
Delay
High alarm delay time for Low Temperature
operation (Dual Temp)
d
LT Control Temperature Low Alarm
Delay
Low alarm delay time for Low Temperature
operation (Dual Temp)
d
MT Control Temperature High Alarm
Threshold
High alarm threshold for Medium Temperature
operation (Dual Temp)
M
MT Control Temperature Low Alarm
Threshold
Low alarm threshold for Medium Temperature
operation (Dual Temp)
M
MT Control Temperature High Alarm
Delay
High alarm delay time for Medium Temperature
operation (Dual Temp)
Md
MT Control Temperature Low Alarm
Delay
Low alarm delay time for Medium Temperature
operation (Dual Temp)
Md
Superheat High Alarm Threshold
High superheat alarm threshold
Superheat Low Alarm Threshold
Low superheat alarm threshold
Superheat High Alarm Delay
High superheat alarm delay time
d
Superheat Low Alarm Delay
Low superheat alarm delay time
d
Low Temperature Suction Pressure
High Alarm Threshold
High Pressure alarm threshold for Low
Temperature operation (Dual Temp)
Low Temperature Suction Pressure
Low Alarm Threshold
Low Pressure alarm threshold for Low
Temperature operation (Dual Temp)
Medium Temperature Suction
Pressure High Alarm Threshold
High Pressure alarm threshold for Medium
Temperature operation (Dual Temp)
M
Medium Temperature Suction
Pressure Low Alarm Threshold
Low Pressure alarm threshold for Medium
Temperature operation (Dual Temp)
M
Suction Pressure Alarm Delay
Pressure alarm time delay
Time which pressure must
transgress any pressure
alarm threshold before
triggering a pressure alarm
d
Lighting Schedule Type
Schedule type
Simple daily schedule (same
On/Off time each day) or
programmable On/ Off time
per day
h
Lighting Off Schedule 1 – 7
Lighting OFF Time/Day
Not available using DM
Lighting On Schedule 1 – 7
Lighting ON Time/Day
Not available using DM
Lighting Simple Daily On Time
Lighting ON Time
Lighting Simple Daily Off Time
Lighting OFF Time
Occupied Light Level
LED Lighting level when shopper presence
detected.
Determines 0 – 10V output
to dimmable LED power
supply expressed as a
percentage 0 – 100%
Time Unoccupied
Time before lighting returns to unoccupied level
when no shopper present.
Determines timing between
changes from occupied to
unoccupied light level.
u
Unoccupied Light Level
LED Lighting level when no shopper presence
detected.
Determines 0 – 10V output
to dimmable LED power
supply expressed as a
percentage 0 – 100%
Uo