192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07
09.10.19 09:27
91 (109)
7.4.4.
Braking resistor ACB-0001-1 and ACB-0002-1
Pulse power (W) Tu ~ 40 °C
*referring to a cycle time
of120 s (reference value)
ED 6 %*
3600
ED 15 %*
2000
ED 25 %*
1200
ED 40 %*
800
Nominal continuous output (W) Ta ~ 40°C
400
Nominal resistance value at 20°C
ACB-0001-01: 30
Ω
ACB-0002-01: 15
Ω
Nominal tolerance at 20°C
±10%
Type of protection (EN 60529) (in the
corresponding bolted state)
IP 54
Max. permitted operation voltage
UL 600 / 1000 V
Cooling
Natural convection
Housing temperature at a continuous nominal
output
Tu ~ 40 °C
approx. 340 °C
Electrical connection
2x AWG 16 / l=25 cm
Operating temperature range
-25 ... +40 °C
Test voltage
2.7 kV AC 1 s
Certification / Marking
UL; CSA
Weight
1.1kg
Mounting positions
Scale drawing:
Stated in mm