xv)
GetElapsedHoursRun
Requests the number of hours the dryer has been ONLINE and cycling
since the last energy savings reset, the returned value will be from 0 to
99999.
xvi)
GetElapsedHoursRegenerating
Requests the number of hours the dryer has been ONLINE and regenerating
since the last energy savings reset, the returned value will be from 0 to 99999.
xvii) GetFault*
The content of Fault Register * is displayed, as a text string. A list of the
fault text strings is given in “DHPNDRL1V3_3.cod” under [ERROR].
N.B. If the fault is still active, ACTIVE will be displayed before the fault
text string. If the fault has been cleared, CLEARED will be displayed before
the fault text string.
xix)
GetFault*Hours
Requests the time/hours at which the event recorded in Fault Register *
was recorded, the returned value will be from 0 to 24.
xx)
GetFault*Minutes
Requests the time/minutes at which the event recorded in Fault Register *
was logged, the returned value will be from 0 to 59.
xxi)
GetFault*Day
Requests the date/day on which the event recorded in Fault Register 1
was logged, the returned value will be from 1 to 31.
xxii) GetFault*Month
Requests the date/month on which the event recorded in Fault Register *
was logged, the returned value will be from 1 to 12.
xxiii) GetFault*Year
Requests the date/year in which the event recorded in Fault Register * was
logged, the returned value will be from 0 to 99.
N.B.
The * represents a number from 1 to 10, representing the 10 fault
registers addressable with PNEUDRI electronic Microprocessor dryers.
21