Instruction Manual

Oildyne 108/118 and 165/175 Series  
Hydraulic Power Units

Bulletin HY22-3210A/US

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Installation

cap/breather. The filler cap may be located in the adapter 

casting between the UP and DN ports, next to the DN port on 

the motor side, or in the reservoir. 

The type of fluid must be compatible with the Nitrile (Buna 

N) seals used on the power unit, and must comply with the 

recommendations of the manufacturers of the component 

parts.  Acceptable fluids include standard Automatic 

Transmission Fluid (ATF) and most mineral based hydraulic 

fluids with viscosities between 32 cSt (150 SSU) and 64 cSt 

(300 SSU) at 38°C (100°F). For fluids other than these, contact 

Parker Oildyne with the details. If users wish to use alternative 

oil, hydraulic fluid or ATF, they are warned to check that they 

have the same properties as those recommended.  

Parker 

Oildyne takes no responsibility if unapproved alternatives 

are used.

Reservoir Filling

The filler location may be between the UP and DN ports as 

shown in 1) below, next to the DN port on the motor side as 

shown in 2) or in the reservoir as shown in 3), 4) and 5):

1)  Will be either a 1/8-27 NPT thread with an 11 mm (7/16 in) hex 

head or a 1/4-18 NPT thread with a 14 mm (9/16 in) hex head. 

Tighten until snug. See below:

2)  A breather/dipstick is installed in 108/118 Series Power Units 

using the ‘A’ and ‘B’ reservoirs in a vertical configuration. The 

dipstick head requires a flat-blade screwdriver with a blade 

width of between 9-13 mm (.35 to .5 in). After filling, with the 

dipstick tightened all the way in, loosen the dipstick by 1.5 turns 

to enable the breather function. See below:

3)  1/4-18 NPT thread with a 14 mm (9/16 in) hex head. Tighten 

until snug. See below:

4)  The cylindrical steel reservoirs have filler/breathers with a 

3/8-18 NPT thread. The head of the breather is circular allowing 

the breather to be removed and installed by hand only – no tools 

are necessary. Tighten until snug. See below:

5)   The rectangular plastic reservoirs have a  filler/breather 

which is a ‘push in/pull out’ design, installable by hand – no 

tools are required. See below:

Reservoir volumes

Vertical Mount (approximate)

In general, when filled to about 12 mm (.5 in) from the filler port 

location. 

Exceptions:

A and B reservoirs filled to “FULL” mark on dipstick.

P, Q, R and S tanks filled to the shoulder below the filler/

breather. See below:

Vertical Mount (motor above reservoir)

Total Volume

Usable Volume

Code

Liter

Gallon

Liter

Gallon

A

.45

.12

.34

.09

B

.72

.19

.60

.16

C

.75

.2

.41

.11

D

.75

.2

.41

.11

F

1.6

.44

1.5

.41

G

.87

.23

.75

.20

H

1.9

.50

1.7

.45

I

3.8

1.0

3.7

.98

J

5.6

1.5

5.3

1.4

P

1.0

.28

.95

.25

Q

2.2

.58

1.9

.51

R

4.9

1.3

4.5

1.2

S

3.5

.94

3.2

.87

Horizontal Mount (approximate)

In general, when filled to about 12 mm (.5 in) from the filler port 

location. 

Exceptions: when the filler port is located between the UP and 

DN ports, fill until oil just becomes visible. See below:

Summary of Contents for Oildyne 108 Series

Page 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Page 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Page 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Page 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Page 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Page 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Page 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Page 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Page 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Page 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Page 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Page 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Page 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Page 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Page 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Page 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Page 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Page 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Page 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Page 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Page 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Page 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Page 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Page 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Page 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...

Page 26: ...26 Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Notes...

Page 27: ...t If a request is received documentation will be transmitted either electronically or by post Description Oildyne 108 118 165 175 Series Power Units Model Number As Applies Sizes All Serial Number All...