background image

12

Instruction Manual

Oildyne 108/118 and 165/175 Series  
Hydraulic Power Units

Bulletin HY22-3210A/US

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Installation

 108/118 Series HD Motors (230 VAC)

1) For Single Direction only, and Reversible with UP port 

pressure:

 

MOTOR

 

2

 

3

 

4

 

BLUE

 

WHITE

 

BLACK

 

GREEN/YEL.

 

RED

 

YELLOW

 

ORANGE

 

161 - 193 MFD/230V

 

4 AMP

 

RELAY

 

L - 1

 

L - 2

 

230 VOLTAGE CONNECTION 

B

 

R

 

O

 

W

 

N

 

2) Reversible with DN port pressure (Black and Red wires are 

interchanged):

 

230 VOLTAGE CONNECTION 

MOTOR

 

2

 

3

 

4

 

BLUE

 

WHITE

 

BLACK

 

GREEN/YEL.

 

RED

 

YELLOW

 

ORANGE

 

161 - 193 MFD/230V

 

4 AMP

 

RELAY

 

L - 1

 

L - 2

 

B

 

R

 

O

 

W

 

N

 

165/175 Series AY Motor

1) For Single Direction only, and Reversible with UP port 

pressure:

Terminal 1 

 Ground

Terminal 2  

+ 12 VDC

2) Reversible with DN port pressure:

Terminal 1  

+ 12 VDC

Terminal 2  

Ground

165/175 Series BY Motor

1) For Single Direction only, and Reversible with UP port 

pressure:

Terminal 1  

Ground

Terminal 2  

+ 24 VDC

2) Reversible with DN port pressure:

Terminal 1  

+ 24 VDC

Terminal 2  

Ground

Suggested reversing electrical schematics

108/118 Series PM Motors

NOTE:

 if a Double Pole, Double Throw toggle switch with a 

current rating for your application is not available, refer to the 

schematic “108/118 AE/BE/IA and 165/175 AY/BY Motors” 

on the next page for a possible reversing circuit using control 

relays.

 
 

 

BLUE 

MOTOR LEAD 

GREEN 

MOTOR LEAD 

RIGHT HAND 

PORT 

LEFT HAND 

PORT 

+12 VDC Supply (AM) 

+24 VDC Supply (B I) 

SOLENOID

 

SWITCH  

SOLENOID

 

SWITCH 

SOLENOID 2

 

SWITCH 

CONTACTS 

NOTE:  AM Motor has an internal 100 

amp thermal breaker; BI Motor has an 
internal 50 amp thermal breaker; IC 

BLACK 

MOTOR LEAD 

Wiring Diagram: AM & BI 

SPDT 

CENTER OFF 

TOGGLE SWITCH

 

SOLENOID 1

 

SWITCH 

CONTACTS 

 

Ground 

+36 VDC Supply (I C) 

Motor has an internal 33 amp thermal
breaker

 

Summary of Contents for Oildyne 108 Series

Page 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Page 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Page 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Page 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Page 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Page 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Page 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Page 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Page 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Page 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Page 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Page 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Page 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Page 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Page 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Page 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Page 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Page 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Page 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Page 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Page 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Page 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Page 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Page 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Page 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...

Page 26: ...26 Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Notes...

Page 27: ...t If a request is received documentation will be transmitted either electronically or by post Description Oildyne 108 118 165 175 Series Power Units Model Number As Applies Sizes All Serial Number All...

Page 28: ...easteurope parker com LV Latvia Riga Tel 371 6 745 2601 parker latvia parker com MX Mexico Apodaca Tel 52 81 8156 6000 MY Malaysia Shah Alam Tel 60 3 7849 0800 NL The Netherlands Oldenzaal Tel 31 0 54...

Reviews: