Instruction Manual

Oildyne 108/118 and 165/175 Series  
Hydraulic Power Units

Bulletin HY22-3210A/US

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Installation

orientation ordered, whether vertical mount (motor above 

reservoir) or horizontal mount (ports facing up).  The power unit 

adapter section, located between the electric motor and the 

reservoir, provides two mounting holes by which the power unit 

can be mounted to the customer’s machine.  These holes are 

located on the mounting foot, 180° from the outlet ports. The 

mounting holes are threaded either 3/8-16 UNC-2B x 7/16 in 

deep (for 108/118 Series ordered with 7/16-20, 7/16-24 or 1/8 in 

NPSF ports and 165/175 Series ordered with 7/16-20 ports) or 

M10 x 1.5 x 15.2 mm deep (for both 108/118 Series and 165/175 

Series ordered with 1/8 in BSPP ports). 

Mount the power unit securely using the threaded holes 

provided in the foot of the adapter. Recommended mounting 

torques are 19.7 – 22.6 Nm (175 - 200 in-lbs) for both the 3/8-16 

bolts and the M10 x 1.5 bolts.

It is strongly recommended that the surface to which 

the power unit is mounted be bonded to earth to provide 

proper grounding in the event of a lightning strike.

Electrical Service Connections 

Connect the motor to the power source following the good 

practices as outlined in the national electric codes and any local 

codes which may apply.  Verify that the available voltage is the 

same as the voltage identified on the label. 

Refer to the performance data on pages 17 - 20 for your 

particular model to determine the current ratings needed 

for your electrical controls.  Parker Oildyne does not supply 

controls for the 108/118 and 165/175 Series Power Units.  

However, the HA and HD motors (both AC) are shipped with a 

start relay and a start capacitor assembly specific to the motor 

voltage being used.  These two components MUST be included 

in the controls circuit designed by the customer. Attempting to 

operate the HA and HD motors without the supplied start relay 

and start capacitor will result in unsatisfactory performance and 

excessive motor heat.  

Parker Oildyne will not warranty a 

power unit which has not been wired properly.

Motor Electrical Connections

AE

2 leads: 12 gauge

BE, IA

2 leads: 14 gauge

AM, BI

3 leads: 12 gauge

AY, BY

2 terminals: 5/16-18 UNF-2A

HA, HD

7 leads: 18 gauge

BASIC MOTOR CONNECTIONS, BY MOTOR CODE (refer to 

model code on shipping/ordering paperwork)

108/118 Series PM Motors: AE only (12 VDC)

1) For Single Direction only, and Reversible with UP port 

pressure:

BLUE    

+ 12 VDC

GREEN    

Ground

2) Reversible with DN port pressure:

BLUE    

Ground

GREEN    

+ 12 VDC

108/118 Series PM Motors: BE/IA only (24/36 VDC)

1) For Single Direction only, and Reversible with UP port 

pressure:

BLACK    

+ 24 or 36 VDC

ORANGE  

Ground

2) Reversible with DN port pressure

BLACK    

Ground

ORANGE  

+ 24 or 36 VDC

108/118 Series SW Motors: AM/BI (12/24 VDC)

1) For Single Direction only, and Reversible with UP port 

pressure:

BLUE    

+ 12 or 24 VDC

GREEN    

unused

BLACK    

Ground

2) Reversible with DN port pressure:

BLUE    

unused

GREEN    

+ 12 or 24 VDC

BLACK    

Ground

108/118 Series HA Motors (115 VAC)

1) For Single Direction only, and Reversible with UP port 

pressure:

 

 

MOTOR 

BLUE 

WHITE 

BLACK 

GREEN/YEL. 

RED 

YELLOW 

ORANGE 

161 - 193 MFD/125V 

7 AMP 

RELAY 

L - 1 

L - 2 

115 VOLTAGE CONNECTION 





2) Reversible with DN port pressure (Black and Red wires are 

interchanged):

 

 

 

BLUE 

WHITE 

BLACK 

GREEN/YEL. 

RED 

YELLOW 

ORANGE 

161 - 193 MFD/125V 

7 AMP 

RELAY 

L - 1 

L - 2 

115 VOLTAGE CONNECTION 





MOTOR

Summary of Contents for Oildyne 108 Series

Page 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Page 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Page 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Page 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Page 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Page 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Page 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Page 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Page 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Page 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Page 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Page 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Page 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Page 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Page 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Page 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Page 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Page 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Page 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Page 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Page 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Page 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Page 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Page 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Page 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...

Page 26: ...26 Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Notes...