71
Command
Service
Index
Subind.
Byte
PDO
See page
Loop counter for a running REPEAT loop
rd
0x2015
0
2
-
Mask inputs
rd/wr
0x2040
0
2
-
Mask outputs
rd/wr
0x2041
0
2
-
Max motor speed value
rd/wr
0x6080
0
2
-
Max speed value
rd/wr
0x607F
0
4
-
Motor nominal current
rd/wr
0x6075
0
2
-
Number of axis motion cycles
rd
0x2013
0
4
-
One digit. a digital output
wr
0x2042
1...16
1
-
Operation mode display
rd
0x6061
0
2
-
Operation mode selection code
rd/wr
0x6060
0
2
-
Polarities
rd/wr
0x607E
0
1
-
Position actual value
rd
0x6064
0
4
T
Position limit value min-max
rd/wr
0x607D
1...2
4
-
Position of the absolute value sensor
rd
0x2022
0
4
-
Positioning window
rd/wr
0x6067
0
4
-
Ramp form speed
rd/wr
0x6086
0
2
-
Rapid stop
rd/wr
0x6085
0
4
-
Rated torque motor
rd/wr
0x6076
0
2
-
Read and write curve memory
rd/wr
0x2056
0
3
-
Read/write parameters in binary format
rd/wr
0x2006
1...250
4
R
Read/write program memory (binary)
rd/wr
0x2050
1...250
20
-
Reduce traverse speed
rd/wr
0x2031
0
1
R
Reference measurement offset
rd/wr
0x607C
0
4
-
Reference run selection code
rd/wr
0x6098
0
2
-
Reference run speed
rd/wr
0x6099
1...2
4
-
Run program record N
wr
0x2052
0
1
R
Set and read curve memory pointer
rd/wr
0x2055
0
2
-
Set and read pointer
rd/wr
0x2051
0
1
-
Set point speed and position default
wr
0x2023
0
6
R
Settings for processing RPDO
rd/wr
0x200F
0
2
-
Special commands for COMPAX XX70
wr
0x2024
1...6
4
-
Speed step profile
wr
0x2033
0
8
-
Speed step profile with ACCEL
wr
0x2034
0
10
-
Start program from record N
wr
0x2053
0
1
R
Status bits 1 and status bits 2.
rd
0x2016
1...2
1
-
Status byte
rd
0x2001
0
1
T
Status word
rd
0x6041
0
2
T
Synchronization with automatic reverse travel
wr
0x2025
0
4
-
Synchronization without automatic reverse travel
wr
0x2026
0
4
-
Target position
rd
0x2020
0
4
-
Target position default
rd/wr
0x607A
0
4
R
Temperature of the power output stage
rd
0x2011
0
2
-
Torque actual value
rd
0x6077
0
2
-
Torque max. value
rd/wr
0x6072
0
2
-
Transfer current position in record N
wr
0x2054
0
1
-
Traverse speed
rd/wr
0x2030
0
2
R
Traverse speed
rd/wr
0x6081
0
4
-
Traverse speed actual value
rd
0x606C
0
4
-
The PDO column indicates whether the corresponding object can be imaged on a process data object. The information in the
PDO column means the following:
•
T
Object can be imaged on a transmit PDO.
•
T
Object can be imaged on a receive PDO.
•
T/R
Object can be imaged on a receive and a transmit PDO.
•
-
imaging on a PDO is not possible.