![Parker Hauser COMPAX-S Series User Manual Download Page 66](http://html1.mh-extra.com/html/parker/hauser-compax-s-series/hauser-compax-s-series_user-manual_4003474066.webp)
Device Profile DSP 402
COMPAX CANopen
66
7 D e v i c e P r o f i l e D S P 4 0 2
From COMPAX program version V3.01 onwards, the operating mode 'Device Profile DSP 402' is available in all COMPAX
variations. It can be activated
via P190=22
. It should be observed here that P190 must already be set to this value at 'Power-
On' in order for the switch on procedure defined in the DSP402 profile is run completely (this is different from the normal
behavior of the COMPAX after 'Power-On').
In accordance with DSP 402 specification there are a series of states which are assumed by the device in sequence. The
corresponding status equipment is integrated in the COMPAX. These states are described in the documentation for 'DSP402'
using diagrams and tables. The following description of the device states is therefore only intended as a supplement to the
DSP402 documentation:
Conditions diagram
START
NOT READY TO SWITCH ON
xx00h
statusword
SWITCH ON DISABLED
READY TO SWITCH ON
SWITCHED ON
OPERATION ENABLE
FAULT REACTION ACTIVE
FAULT
statusword
statusword
statusword
statusword
statusword
statusword
xx60h*
xx21h
xx23h
xx27h
QUICK STOP ACTIVE
xx07h
xx28h
controlword
xx1x x1xx
controlword
lock voltage
xxxx xx0x
quick stop
xxxx x01x
controlword
lock voltage
xxxx xx0x
controlword
lock voltage
xxxx xx0x
quick stop
xxxx x01x
controlword
shutdown
xxxx x110
controlword
shutdown
xxxx x110
controlword
switch on
xxxx x111
controlword
shutdown
xxxx x110
controlword
operation enable
xxxx 1111
controlword
operation disable
xxxx 0111
controlword
quick stop
xxxx x01x
controlword
reset fault
0xxx xxxx
1xxx xxxx
controlword
lock voltage
xxxx xx0x
Note!
P189=0 produces "xx00h" here: P189=15 will give you xx60h.
When operating mode 'Device Profile DSP 402' is activated, the COMPAX command OUTPUT A0=... must not be used.