67
Status
Description
NOT READY FOR
SWITCHING ON:
!
Self-test is running
!
Initialisation is running
!
Drive function is disabled
!
All functions are disabled
SWITCHING ON DISABLED:
!
Software/hardware initialization is terminated
!
Communication via all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled (motor dead)
!
Display shows 'OFF'
READY TO SWITCH ON:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled (motor dead)
!
Display shows 'OFF'
SWITCHED ON:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled (but motor has current)
!
Display shows 'run'
OPERATION ENABLE:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is enabled (motor has current)
!
Display shows 'run'
QUICK STOP ACTIVE:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive implements the STOP function (motor has current)
!
Display shows 'run'
FAULT:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled
!
Display shows 'Exx'
ERROR REACTION:
!
Error handling only, no static device status