50
Gemini GT Hardware Installation Guide
Power Specifications
Input Power
AC
Drive
AC Input Range
GT-L5
95VAC – 132VAC, 50/60 Hz, single phase
GT-L8
95VAC – 132VAC, 50/60 Hz, single phase
GT-U5
95VAC – 132VAC and 190VAC – 264VAC, 50/60 Hz, single phase
GT-U8
95VAC – 132VAC and 190VAC – 264VAC, 50/60 Hz, single phase
Connector
Drive connector:
#8 (M4) screw terminals.
Mating terminals:
spade fork, 0.325” maximum width
CAUTION
Do not operate GT-U5/8 in the 132VAC – 190VAC range, or the drive will be
permanently damaged.
CAUTION
You must connect V DBL to L2/N on GT-U5/8 to enable the voltage doubler for
120VAC operations.
CAUTION
Do not operate GT-L5/8 above 132VAC, or the drive will be permanently damaged.
+24VDC “Keep Alive” Power
Input voltage range:
19.2 – 28.8 VDC
Input current:
500 mA (maximum)
Output Power
Output Current
Output Voltage (motor bus)
Drive
(amps, peak)
(DC, rms)
GT-U5
5.0
74
GT-U8
7.5
74
GT-L5
5.0
170
GT-L8
8.0
170
Connector
Drive connector:
#8 (M4) screw terminals.
Mating terminals:
spade fork, 0.325” maximum width
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com