19
2.3
Motor and feedback mounting
In this chapter you can read about:
Motor / gearbox mounting with inline motor configuration................................................. 20
Motor / gearbox mounting with parallel motor configuration ............................................. 21
Notes on motor wiring
In order to adhere to the EMC directive, it is necessary to mount the motor if ever
possible unchanged. If you require a longer cable, the entire line should be
replaced with the same or a similar cable.
If you mount a connector on the new cable, please make sure that the 360 °
motor cable shielding is maintained and that there is no connection to earth via
the connector housing.
The motor must be grounded with a separate PE protective lead
(green/yellow, cross-section at least 2.5 mm
2
).
This cable must be connected to the available motor-ground connector or - if there
is none available - with a mounting screw. In the latter case, the coloring under the
head of the screw must be removed.
If the axis is mounted upright, it must be secured against moving out!