If the motor used with the electro cylinder should be able to exceed individual limit values of
the cylinder, the respective values for the motor must be limited in the control by
appropriate parameterization. The parameterization should even be reduced down to the
values necessary for operation.
This would, for example provide a hint to a possible damage or to preventive maintenance
if wear-induced extensive friction of the machine or cylinder would trigger an error message
of the controller.
The internal end stops of the electro cylinder may under no circumstances be
accessed during operation. The internal end positions may only be accessed by the
cylinder in setup mode and only for determining the end positions with a low force of
a few N (torque limitation if possible below 10%) and very slowly (max. 2% of the
nominal speed).
The lifetime of the electro cylinder depends strongly on the degree of power exploitation
and on impermissible operating states occurring - even if only for a short time.