29
DeviceNet Communications Interface
VALUE Type Connector
Data from PLC
Data to 890
From BOOL to VALUE
False
True
0.0
1.0
From SINT to VALUE
-128 to 127
-128.0 to 127.0
From INT to VALUE
-32,768 to 32,767
-32,768.0 to 32,767.0
From DINT to VALUE
-2,147,483,648 to
2,147,483,547
-32,768.0 to 32,767.0
limits apply
From USINT to VALUE
0 to 255
0.0 to 255.0
From UINT to VALUE
0 to 65,535
0.0 to 32,767.0
limits apply
From UDINT to VALUE
0 to 4,294,967,295
0.0 to 32,767.0
limits apply
From REAL to VALUE
32-bit IEEE floating-point
-32,768.0 to 32,767.9999
Data from 890
Data to PLC
From VALUE to BOOL
Zero
Non-zero
False
True
From VALUE to SINT
-32,768.0 to 32,767.9999
-128 to 127
limits apply/ rounding applies
From VALUE to INT
-32,768.0 to 32,767.9999
-32,768 to 32,767
limits apply/ rounding applies
From VALUE to DINT
-32,768.0 to 32,767.9999
-32768 to 32,767
limits apply/ rounding applies
From VALUE to USINT
-32,768.0 to 32,767.9999
0 to 255
limits apply/ rounding applies
From VALUE to UINT
-32,768.0 to 32,767.9999
0 to 32767
limits apply/ rounding applies
From VALUE to UDINT
-32,768.0 to 32,767.9999
0 to 32767
limits apply/ rounding applies
From VALUE to REAL
-32,768.0 to 32,767.9999
32-bit IEEE floating-point