ASCII
15
RS485/RS232 Communications Interface
EI Bisynch ASCII Parameter Mapping
1. EI Bisynch ASCII Prime Set
The following prime set parameters are supported:
Mnemoni
c
Description
Range (HEX encoding)
Access
II
Instrument Identity >0650, >1650 or >2650
0650 = 650 Frames 1, 2 & 3
1650 = 650V Frames 1, 2 & 3
2650 = 650V Frames C, D, E & F
Read Only
V0 Main
Software
Version
>0000 to >FFFF
Read Only
V1 Keypad
Software Version
>0000 to >FFFF
(>0000 if not fitted)
Read Only
EE
Last Error Code
>0000 to >FFFF
(Writing any value resets this to
>00C0)
Read/Write
2. Command/Status
The following Command/Status parameters are supported:
Mnemonic
Description
Range (Hex encoding)
Access
!1
Command
see below
Write Only
!2
State
see below
Read Only
!3
Save Command
see below
Write Only
!4
Save State
see below
Read Only
!1 : Command
Write-only: used to modify the state of the drive and to load configuration data from
non-volatile memory.
HEX Value Description
>7777
Reset Command. Acknowledges failed restore. Loads and saves
default Product Code and default Configuration (Application 1).
>0101
Restores Saved Configuration from drive’s non-volatile memory.
>0110
Restores Default Configuration (Application 0)
>0111
Restores Default Configuration (Application 1)
>0112
Restores Default Configuration (Application 2)
>0113
Restores Default Configuration (Application 3)
>0114
Restores Default Configuration (Application 4)
>0115
Restores Default Configuration (Application 5)
>4444
Exit Configuration Mode
>5555
Enter Configuration Mode
!2 : State
Read-only: used to determine the major state of the Inverter.
HEX Value Description
>0000
Initialising. (Powering up )
>0001
Corrupted Product Code and Configuration
>0002 Corrupted
Configuration
>0003 Restoring
Configuration
>0004 Re-Configuring
Mode
>0005
Normal Operation Mode