9-14
Technical Specifications
650V AC Drive
Analog Inputs/Outputs
Inputs
Output
Range
0-10V and 0-5V (no sign) set via parameter
S
IP13 (AIN1)
0-10V, 0-5V, 0-20mA or 4-20mA (no sign) set via
parameter
S
IP23 (AIN2)
Absolute maximum input current 25mA in current mode
Absolute maximum input voltage 24V dc in voltage mode
0-10V (no sign)
Maximum rated output
current 10mA, with short
circuit protection
Impedance
Voltage range = 31.8k
Ω
Current range = 200
Ω
Voltage range = 100
Ω
Resolution
10 bits (1 in 1024)
10 bits (1 in 1024)
Dynamic Response
5ms
Bandwidth 15Hz
Digital Inputs
Operating Range
DIN1, DIN2, DIN3, DIN4, DIN5:
0-5V dc = OFF, 15-24V dc = ON
(absolute maximum input voltage ±30V dc)
IEC1131
DIN6, DIN7:
0-1.5V dc = OFF, 4-24V dc = ON
(absolute maximum input voltage ±30V dc)
IEC1131
undefined state
15V
5V
0V
24V
ON
OFF
undefined state
4V
1.5V
0V
24V
ON
OFF
Input Impedance
6.8k
Ω
Sample Interval
5ms
Relay
RL1A, RL1B : These are volt-free relay contacts. 50V dc max, 0.3A max (for inductive loads
up to L/R=40ms, a suitable freewheel diode must be used).
Maximum Voltage
250V ac
Maximum Current
4A resistive load
Digital Outputs
DOUT1 and DOUT2 (DOUT1 is only configurable using DES Lite or other suitable
programming tool).
Nominal Open Circuit Output Voltage
23V (minimum 19V)
Nominal Output Impedance
33
Ω
Rated Output Current
150mA : The total current available is 150mA, either individually or
as the sum of terminal 6 & 10.