![Parker 650V series Product Manual Download Page 34](http://html2.mh-extra.com/html/parker/650v-series/650v-series_product-manual_3741148034.webp)
5-4
The Keypad
650V AC Drive
The Menu System
Diag
Press
to show following:
Par
Press
to show following:
SET
See chapter 6 for instructions to view full menu
Press
to show following:
App
This menu is configured by the App
Menu blocks in DSE Lite. Also
applications 3, 4, 5 & 6 populate
this menu as shown.
Press
to show following:
Hz Drive
frequency
%
Speed setpoint
v DC link volts
A
Motor current
To see the following menu
requires detailed menus view
to be enabled:
To enable arrow to
Set
press
arrow to
ST99
and
press
key.
IN
DIN
Digin
word
IPA1
Anin 1 value
IPA2
Anin 2 value
OUT
DOUT
Digout
word
OPA1
Anout 1 value
OPA2
Anout 2 value
TRIP
TH1
Trip
1,
(newest)
TH2
Trip 2
TH3
Trip
3
TH4
Trip
4
TH5
Trip 5
TH6
Trip
6
TH7
Trip 7
TH8
Trip 8
TH9
Trip
9
TH10
Trip 10, (oldest)
P
1
Application
P
2
Max speed
P
3
Min speed
P
4
Accel time
P
5
Decel time
P
6
Motor current
P
7
Base frequency
P
8
Jog setpoint
P
9
Run/stop mode
P
11 V/F
shape
P
12 Normal
duty
P
13 Fixed
boost
P
14 Auto
boost
P
99 Password
CTRL
CL01
Control
mode
CL02
Nameplate
RPM
CL03
Fly-catch
enable
CL04
Slip comp enable
CL05
Stabilisation
enable
CL06
Voltage control mode
CL07
Boost
mode
CL08
Auto boost
CL09
Energy
saving
CL10
Motor
current
CL11
Motor
poles
CL12
Motor
voltage
CL14
Mag
current
CL15
Power
CL16
Motor
connection
CL17
Stator
resistance
CL18
Leakage
inductance
CL19
Mutual
inductance
CL1A
Rotor time constant
CL20
Autotune
mode
CL21
Autotune
enable
CL81
Current
limit
CL82
Positive torque limit
CL83
Negative torque limit
CL84
Stall trip type
CL91
Speed prop gain
CL92
Speed
integral
time
CL93
Speed positive limit
CL94
Speed
negative
limit
IN
IPO1
Digin 1 invert
IPO2
Digin 2 invert
IPO3
Digin 3 invert
IPO4
Digin 4 invert
IPO5
Digin 5 invert
IPO6
Digin 6 invert
IPO7
Digin 7 invert
IP11
Anin
1
scale
IP12
Anin 1 offset
IP13
Anin
1
type
IP21
Anin
2
scale
IP22
Anin 2 offset
IP23
Anin 2 type
IPD1
Digin 1 value
IPD2
Digin 2 value
IPD3
Digin 3 value
IPD4
Digin 4 value
IPD5
Digin 5 value
IPD6
Digin 6 value
IPD7
Digin 7 value
IPa1
Anin1 value
IPA2
Anin2 value
OUT
OPD1
Digout
1
invert
OPD2
Digout
2
invert
OPD3
Relay
invert
AO11
Anout 1 scale
AO12
Anout 1 offset
AO13
Anout 1 abs
AO14
Anout 1 value
AO21
Anout 2 scale
AO22
Anout 2 offset
AO23
Anout 2 abs
AO24
Anout 2 value
CONF
DIN1
Digin 1 destination
DIN2
Digin 2 destination
DIN3
Digin 3 destination
DIN4
Digin 4 destination
DIN5
Digin 5 destination
DIN6
Digin 6 destination
DIN7
Digin 7 destination
DOP1
Digout 1 source
DOP2
Digout 2 source
DOP3
Relay
source
AOP1
Anout 1 source
AOP2
Anout 2 source
TRIP
LOOP
4 to 20mA loop
T 3
Anin 2 overload
STLL
Motor
stalled
OT
Moter
overtemp
IT
Inverse
time
DbR
Dynamic brake resistor
DB S
Dynamic brake switch
SPD
Speed
feedback
OSPD
Over speed
DISP
Display
/
keypad
DCRP
DC link ripple
SERL
SE01
Remote comms sel
SE02
Comms
timeout
SE03
Comms
address
SE04
Comms
baud
rate
SE05
Comms
parity
SE06
Reply delay ms
SE07
Protocol,
(OP)
SE08
Protocol,
(P3)
SETP
ST01
Jog accel time
ST02
Jog decel time
ST03
Ramp
time
ST04
S ramp jerk
ST05
S ramp cont
ST06
min speed mode
ST11
Skep freq 1
ST12
Skip freq 1 band
ST13
Skip freq 2
ST14
Skip freq 2 band
ST21
AR
attempts
ST22
AR
delay
ST23
AR
triggers
ST24
AR
t
ST31
DB
Enable
ST32
DB
Resistance
ST33
DB
Power
ST34
DB
Over-rating
ST41
Torque
feedback
ST42
Torque
level
ST43
Use abs torque
ST51
Local min speed
ST52
Enabled
keys
ST98
Application
lock
ST99
Detailed
menus
ENC
EN01
Encoder
mode
EN02
Encoder
reset
EN03
Encoder
invert
EN04
Encoder
lines
EN05
Encoder
speed
scale
EN06
Encoder
speed
AP1
APP menu 1
AP2
APP menu 2
AP3
APP menu 3
AP4
APP menu 4
AP5
APP menu 5
AP6
APP menu 6
AP7
APP menu 7
AP8
APP menu 8
AP9
APP menu 9
AP10
APP menu 10
AP11
APP menu 11
AP12
APP menu 12
AP13
APP menu 13
AP14
APP menu 14
AP15
APP menu 15
AP16
APP menu 16
Default settings
Macro 3:
AP1
Preset 0
AP2
Preset 1
AP3
Preset 2
AP4
Preset 3
AP5
Preset 4
AP6
Preset 5
AP7
Preset 6
AP8
Preset 7
Macro 4:
AP1
RL ramp rate
AP2
RL max value
AP3
RL min value
AP4
RL reset value
Macro 5:
AP1
PI P gain
AP2
PI I gain
AP3
PID D gain
AP4
PID D filter TC
AP5
PID
fbk
gain
AP6
PID limit
AP7
PID low limit
AP8
PID symmetric limit
AP9
PID scale
AP10
PID error
AP11
PID
output
Macro 6:
AP1
Command
AP2
Setpoint
AP3
Status
Use the arrow down key
to go left and arrow up key
to go right
NOTE:
To move
up and
down the
lists
arrow up
to go
down
and
arrow
down
to go up.
Software Version Number
This is displayed on power-up, for up to 8
seconds. For example, version 5.2:
It can also be displayed by pressing the E
key for 2 seconds when at the top of the
MMI tree, Menu Level 1.
R5
.
2
Lefflersgatan 1, SE-754 50 Uppsala, SWEDEN
+46 (0)18-65 70 00
+46 (0)18-10 74 78 [email protected] www.regal.se