➂
Installation
7
C H A P T E R
➂
Installation
The information in this chapter will enable you to:
❏
Mount all system components properly
❏
Connect all inputs and outputs properly
❏
Verify that the complete system is installed properly
To ensure proper installation, you should perform all the bench test procedures in Chapter 2,
Getting Started, before proceeding with the permanent installation process in this chapter.
Installation Precautions
To help ensure personal safety and long life of system components, pay special attention to
the following installation precautions.
WARNING
Always remove power to the 6250 before performing wiring installation or changing DIP switch
settings.
Heat & Humidity
Operate the 6250 system at an ambient temperature between 32
°
and 122
°
F (0
°
to 50
°
C). Keep
the relative humidity below 95%.
Electrical Noise
For more information
on electrical noise,
refer to Appendix A.
Minimize the potential for electrical noise before installing the 6250, rather than attempting to
solve such problems after installation. You can prevent electrical noise by observing the
following installation precautions:
❏
Do not route high-voltage wires and low-level signals in the same conduit.
❏
Ensure that all components are properly grounded.
❏
Ensure that all wiring is properly shielded.