![Parker 6250 User Manual Download Page 97](http://html.mh-extra.com/html/parker/6250/6250_user-manual_755628097.webp)
82
6250 Servo Controller User Guide
Example
Command
Description
>
SCALE1
Enable scaling
>
PSCLA25ØØØ
Set path acceleration scale factor to 25000 steps/unit
>
PSCLV25ØØØ
Set path velocity scale factor to 25000 steps/unit
>
@SCLD1ØØØØ
Set distance scale factor to 10000 step/unit on all axes
>
PA25
Set the path acceleration to 25 units/sec2
>
PAD2Ø
Set the path deceleration to 20 units/sec2
>
PV2
Set the path velocity to 2 units/sec
>
D1Ø,5
Set the distance to 10 & 5 units on axes 1 & 2, respectively
>
GOL11
Initiate linear interpolated motion on both axes (see figure below)
(a
GOL
command could have been issued instead of a
GOL11
command)
Y (Axis 2)
X (Axis 1)
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
10
11
12
13
D1Ø,5
DØ,Ø
Velocity
Time
PV, PA
Linear Interpolated Path
Contrasting Motion Profiles of Axes 1 & 2
to Achieve the Linear Interpolated Path
Axis 1
Axis 2