102
6250 Servo Controller User Guide
Outputs (see also
I/O Pin Outs & Circuit Drawings)
26 Programmable
(includes OUT-A and OUT-B on AUX connector)
Command Out (CMD)
Shutdown (SHTNO, SHTNC, and COM)
Optically isolated, TTL-compatible*, open collector output. Can be pulled
up by connecting OUT-P to +5V on the AUX connector, or to a user-
supplied voltage of up to 24V. Max. voltage in OFF state (not sinking
current) = 24V, max. current in ON state (sinking) = 30mA.
50-pin plug
is compatible with OPTO-22™ signal conditioning equipment.
Controllable with the 6000 Series programming language.
±
10V analog output. 12-bit DAC. Load should be > 2K
Ω
impedance.
Shutdown relay output. Max. rating: 175VDC, 0.25A, 3W.
*
TTL-compatible voltage levels: Low
≤
0.4V, High
≥
2.4V
I/O Pin Outs & Circuit Drawings
This section, organized by connector, provides pin outs and circuit drawings for all 6250
inputs and outputs. All inputs and outputs are optically isolated.
Drive Connectors
The following table lists pin outs for the 6250's two 9-pin
DRIVE
connectors. Internal circuits
are shown below.
Pin #
In/Out
Name
Description
1
-----
SHLD
Shield—internally connect to chassis (earth) ground.
2
-----
COM
Signal common to which the shutdown relay outputs are referenced.
3
OUT
SHTNC
Shutdown relay output to drives that require a closed contact to disable the drive(see circuit drawing below). The
shutdown relay is active (disabling the drive) when no power is applied to the 6250. When the 6250 is powered
up, the shutdown relay remains active until you issue the
DRIVE11
command.
Shutdown active (
DRIVEØØ
): This output is internally connected to COM.
Shutdown inactive (
DRIVE11
): This output is disconnected from COM.
4
OUT
SHTNO
Shutdown relay output to drives that require an open contact to disable the drive(see circuit drawing below).
The shutdown relay is active (disabling the drive) when no power is applied to the 6250. When the 6250 is
powered up, the shutdown relay remains active until you issue the
DRIVE11
command.
Shutdown active (
DRIVEØØ
): This output is disconnected from COM.
Shutdown inactive (
DRIVE11
): This output is internally connected to COM.
5
IN
DFT
Drive fault input. Set active level with the
DRFLVL
command. The drive fault input will not be recognized until
you enable the input functions with the
INFEN1
command. — see circuit diagram below
6
-----
AGND
Analog ground.
7
IN
ANI
±
10V, 14-bit analog input. Input value is reported with the
[ANI]
and
TANI
commands. (6250-ANI option only).
8
OUT
CMD-
Command signal return. — see circuit diagram below
9
OUT
CMD+
Command output signal (
±
10V signal). — see circuit diagram below
Shutdown Active (
DRIVEØØ
):
Open
Internal Shutdown Output Circuit
SHTNC
SHTNO
Internal Drive Fault Input Circuit
+5VDC
GND
74HCTxx
6.8 K
Ω
Drive Fault
(DFT)
GND
Internal Command Signal
Output Circuit
AGND
CMD+
CMD-
DRIVE
Connector
+
-
C
+
-
AGND
COM
DRIVE
Connector
51 K
Ω
Closed
Open
SHTNC
SHTNO
COM
Closed
Shutdown Inactive (
DRIVE11
):
Solid State Relay
Solid State Relay
DRIVE
Connector
DRIVE
Connector