10 - Warnings and failures
Strada Transfert Evolution2 - Operation manual
46/50
10.2
Red failure LED
A flashing red LED means that the terminal is out of service. Please contact the
technical department and provide the following information:
Failure code number;
Failure message (the list below contains the most common failures);
If possible, a test ticket.
Failure display:
You can view the
DIAGNOSIS
code in hexadecimal format of a warning or a failure
without opening the maintenance door.
To do so, press the (red)
Cancel
key and the (green)
OK
key of the
function keypad or extended keyboard simultaneously.
Hold the
Cancel
key pressed down till the "Release change button"
message is displayed.
Place the cursor on the
Errors
function in the menu that is displayed by
pressing the
OK
button as many times as required.
Press
Cancel
to select the function.
The terminal will display a list with 20 most recent fault and failure codes.
An alternative solution is to open the maintenance door and select programming
function number
96
with the keyboard.
Code
Failure message
Problem
Solution
4000
ON
-
LOAD BATTERY
MEASUREMENT
The buffer battery voltage
is too low when idle.
Change the battery.
4001
NO
-
LOAD BATTERY
MEASUREMENT
The buffer battery voltage
is too low when idle.
Change the battery.
4101
COINBOX FULL FAILURE
The coinbox cannot accept
any more coins.
Collect the coins.
4103
COLLECTION NOT ENDED
Collection door not
properly closed.
Check if the doors are
closed correctly.
4200
PRINTER FEED SYSTEM
FAILURE
Printer jammed or failed
Check printer operation.
4201
PRINTER CUTTING
SYSTEM FAILURE
Printer jammed or failed
Check printer operation.
4202
PRINTER FEED SENSOR
FAILURE
Printer jammed or failed
Check printer operation.
4203
PRINTER CUTTING
SENSOR FAILURE
Printer jammed or failed
Check printer operation.
4204
NO PAPER
IN PRINTER
No more tickets.
Change the ticket roll.