6 - Coin collection
Strada Transfert Evolution2 - Operation manual
17/50
6.
Coin collection
6.1
Organisation and security
Organisation:
Collections must be organised randomly:
at the time of the collection round;
when a green warning LED flashes to show that the coinbox is almost full;
when a red failure LED flashes to show that the coinbox is full.
In the event of malfunctioning:
If the terminal offers the facility to use several payment methods, the
collection malfunctioning LEDs are
green
and payment with coins is
impossible, but payment by card is possible.
If payment with coins is the only payment method, the malfunctioning LEDs
are
red
.
Security:
Parkeon terminals are designed to offer strong protection from fraud. Special
attention must be paid to the various potential risks of fraud and theft. Some basic
precautions need to be taken:
Always store the keys to doors and drawers in a
secure location
;
Before making a collection with the transfer canister, always check that the
canister is
empty
and that the once-only opening system has been reset
(once-only system reset dot);
Always
check that the padlock of the trolley or canister is locked before
making the collection.
IMPORTANT:
Before beginning the collection procedure, the operating agent must
make sure that the terminal is in proper working order.