MDX DEBRIS REMOVAL SYSTEM MANUAL
1
System Design:
NOTICE:
The MDX Debris Removal System
TM
requires the proper installation of all anti-entrapment features SDX High Flow
Safety Drain
TM
with a listed suction outlet fitting and one of the four vacuum breaker installation methods on the
following pages.
These MDX instructions provide four design methods to choose from. Your local codes may require additional safety
measures. Paramount Pool & Spa Systems and its representatives cannot recommend or endorse installation methods
other than those provided in these MDX instructions.
NOTICE — Maximum Pump Size:
MDX is rated for a maximum of 90 GPM. While system flow rate will vary with pump size and the Total Head Loss for
a given system, virtually any modern pump is capable of exceeding this limit, therefore it is the responsibility of the
system designer to make sure it is not possible to exceed 90 GPM.
MDX DEBRIS REMOVAL SYSTEM INSTALLATION
NOTICE:
18 inches of 2½" pipe is required to be connected to the center outlet of the MDX Debris Removal System
TM
. After
the 18 inches of 2½" pipe you may reduce to a smaller pipe size, although it is not recommended. U
Usse
e o
off 2
2½
½"" p
piip
pe
e
tth
hrro
ou
ug
gh
ho
ou
utt tth
he
e ssu
uc
cttiio
on
n ssiid
de
e o
off tth
he
e ssyysstte
em
m iiss ssttrro
on
ng
gllyy e
en
nc
co
ou
urra
ag
ge
ed
d ffo
orr o
op
pttiim
mu
um
m p
pe
errffo
orrm
ma
an
nc
ce
e.. For your convenience,
Paramount Pool & Spa Systems includes the 18 inches of 2½" pipe plus coupler with the MDX Debris Removal
System. To order separately, please see page 12 for the part number.
MDX Debris Removal System
STANDARD POOL/SPA/BASIN DESIGN
Dual Drain
2 1/2" OR EQUAL
TO CIRCULATION LINE
2nd SUCTION OUTLET
ANY ORIENTATION
SDX
One vacuum
breaker method
must be used.
2" OR LARGER
CIRCULATION LINE
2 1/2" COUPLER
2 1/2" X 18"
Design Flow Rate = 90 GPM
Maximum GPM = 90
Velocity at 90 GPM = 1.386 FPS