IMPORTANT NOTICES: PLEASE READ

WARNING

KNOWN DROWNING HAZARD.

DO NOT GO NEAR THE SUCTION FITTINGS OR DRAINS OF YOUR POOL OR SPA. YOUR HAIR OR BODY

MAY BECOME TRAPPED CAUSING PERMANENT INJURY OR DROWNING.

DO NOT ENTER THE POOL OR SPA IF SUCTION FITTINGS OR DRAIN COVERS ARE LOOSE, BROKEN, OR MISSING.

WARNING

RISK OF SEVERE INJURY OR DROWNING IF SUCTION SYSTEMS ARE NOT INSTALLED PROPERLY!

NOTICE TO OWNER:

READ, FOLLOW, AND SAVE THESE SAFETY INSTRUCTIONS.

Suction can pose a serious hazard to swimmers just as electricity can be a hazard. Both are important for proper water
filtration and both must be treated with respect. Suction safety begins with a professional design that includes a quality
suction system installed by a certified contractor.

The MDX Debris Removal System

TM

is only available to certified contractors for the same reason certified electricians

are required to connect filtration pumps to public utilities; both require proper training and certification to assure no
hidden hazards are built into the project.

Certified builders will address the following issues when designing and installing a proper filtration system:

Properly bond-grounded pumps, time clocks, switches and any other metal in or near water. This is required to
address Electrical Shock Hazards.

Design the suction piping so there are no single-point suction hazards; single-point suction (one drain) is a leading
cause of Body Suction Entrapment Hazards. Note: your certified builder has many effective options for addressing
this hazard; they may include dual-drain systems, like MDX, skimmers, gutters, negative edge features and many
more products and piping designs known to professionals.

Install A

AS

SM

ME

E/

/A

AN

NS

SII  A

A1

11

12

2..1

19

9..8

8M

M listed  drains,  suction  covers  and  debris  removal  systems.  This  is  the  O

ON

NL

LY

Y

approved option for preventing Hair Entrapment Hazards, the leading cause of suction related injuries. 

Design and install an effective circulation system (including optional cleaning systems), to direct filtered water to
all areas and interior surfaces. NOTE: Suction fittings can NOT clean or direct filtered water for proper sanitation;
that can only be done on the pressure (return) side of the filtration system. 

While  suction  injuries  are  extremely  rare,  drowning  and  diving  injuries  are  far  too  common  and  there  is  little  your
certified  builder  can  do  to  eliminate  these  hazards.  You  must  educate  yourself  and  your  guests.  Below  are  some
important safety issues every swimmer must know and recognize.

P

PR

RE

EV

VE

EN

NT

T D

DR

RO

OW

WN

NIIN

NG

G:: Watch children at all times, no swimming alone. 

N

NO

O D

DIIV

VIIN

NG

G IIN

N S

SH

HA

AL

LL

LO

OW

W W

WA

AT

TE

ER

R:: You can be permanently injured. 

P

PR

RE

EV

VE

EN

NT

T S

SU

UC

CT

TIIO

ON

N E

EN

NT

TR

RA

AP

PM

ME

EN

NT

T:: Inspect suction covers before swimming, keep swimmers away from suction

fittings, protect long hair, don’t swim with loose clothing or large and dangling jewelry. 

© 2006, Paramount Pool & Spa Systems

Summary of Contents for MDX DEBRIS REMOVAL SYSTEM

Page 1: ...spa ol Page 11 MDX DEBRIS REMOVAL SYSTEM MANUAL MDX0804 004 027 8750 00 2 07 Notice to Installers Read and follow these instructions Give these instructions to the facility owner Follow all codes and...

Page 2: ...eading cause of Body Suction Entrapment Hazards Note your certified builder has many effective options for addressing this hazard they may include dual drain systems like MDX skimmers gutters negative...

Page 3: ...re it is not possible to exceed 90 GPM MDX DEBRIS REMOVAL SYSTEM INSTALLATION NOTICE 18 inches of 2 pipe is required to be connected to the center outlet of the MDX Debris Removal SystemTM After the 1...

Page 4: ...5 1 2 FT MAX 2 1 2 2 1 2 DEBRIS CANISTER SDX MDX VACUUM BREAKER VENT TO AIR 12 MINIMUM DEPTH TO AVOID AIR VORTEX LOWEST WATERLINE 5 FT MIN 5 1 2 FT MAX 2 1 2 2 2 1 2 DEBRIS CANISTER POOL SPA BASIN SDX...

Page 5: ...18 2 1 2 POOL WITH CANISTER WITHOUT CANISTER SDX 2nd SUCTION OUTLET SDX VACUUM BREAKER MDX 2 2 1 2 2 1 2 x 18 2 1 2 2 DEBRIS CANISTER SDX SDX VACUUM BREAKER MDX 2 1 2 2 1 2 x 18 2 1 2 2 12 MINIMUM DE...

Page 6: ...N OUTLET SDX 2nd SUCTION OUTLET MDX MDX DEBRIS CANISTER 2 2 1 2 x 18 2 1 2 x 18 2 1 2 2 1 2 2 1 2 SDX 2nd SUCTION OUTLET MDX SDX 2nd SUCTION OUTLET DEBRIS CANISTER MDX 2 1 2 2 1 2 x 18 2 1 2 x 18 2 1...

Page 7: ...of Teflon tape Insert plug into threaded socket Set plug wrench on lug and tighten by hand until snug Apply handle to wrench and turn 1 5 to 2 turns Do not under or over tighten plug OR USE ALTERNATE...

Page 8: ...ll Sump Fig 1 Form a concrete sump around each suction pipe Concrete Shell Preparation Fig 2 Prior to installing the interior finish cut each SDX riser pipe approximately 1 behind the concrete shell s...

Page 9: ...Ring 4 Form a watertight seal around the suction pipe 5 Wipe clean any finishing material that remains on the SDX Concrete Ring s top edge and mounting surface Concrete Cover Assembly Fig 4 1 Align th...

Page 10: ...the pool spa or basin 3 Use a sealing compound compatible with the interior surface to lock the Concrete Ring in place and to provide a water tight seal Sealing compound example Topping Mix Cement hyd...

Page 11: ...dditional questions should be forwarded to Paramount s corporate office at 1 800 621 5886 PARAMOUNT CANISTER WINTERIZATION TEST PLUGS 2 GALV SQ HEAD BALANCE LINE TO MAIN DRAIN TO OPTIONAL SKIMMER OR V...

Page 12: ...Head 12 pk 8 N A Support 9 005 202 1154 00 Plaster Cap 10 005 202 1148 00 Sump Construction Cap 11 005 252 1611 00 Plug Pressure Test 2 w O Ring 4 pk 12 005 252 1605 00 Plug 2 6 pk 13 006 202 6180 00...

Page 13: ...ANUAL PARA EL SISTEMA MDX DE RECOGIDA DE ESCOMBROS MDX0804 004 027 8750 00 2 07 Aviso a los instaladores Lea y siga estas instrucciones D le estas istrucciones al due o a Siga todos los c digos y regl...

Page 14: ...s comunes de Atrapamiento del Cuerpo AVISO su contratista certificado tiene muchas opciones efectivas acerca de este peligro pueden incluir sistemas de dos desag es como MDX espumaderas alcantarillas...

Page 15: ...por minuto LA INSTALACI N DEL SISTEMA MDX AVISO Se recomiendan 18 pulgadas de tuber a de 2 para conectarse al desag e de en medio del Sistema de MDX de eliminaci n de escombro Despu s de instalar 18 p...

Page 16: ...O CONTRA ROMPIMIENTO DEL EFECTO DE ASPIRACI N VENTILACI N AL AIRE PROFUNDIDAD DE 12 M NIMO PARA PREVENIR REMOLINO DE AIRE LINEA DE AGUA M S BAJA 5 FT MIN 5 1 2 FT MAX 2 1 2 2 2 1 2 CONTENEDOR DE ESCOM...

Page 17: ...SUCCI N SECUNDARIA SDX SEGURO CONTRA ROMPIMIENTO DEL EFECTO DE ASPIRACI N MDX 2 2 1 2 2 1 2 x 18 2 1 2 2 CONTENEDOR DE ESCOMBROS SDX SDX SEGURO CONTRA ROMPIMIENTO DEL EFECTO DE ASPIRACI N MDX 2 1 2 2...

Page 18: ...MDX CONTENEDOR DE ESCOMBROS MDX 2 1 2 2 1 2 x 18 2 1 2 x 18 2 1 2 2 1 2 2 SDX DESEMBOCADURA DE SUCCI N SECUNDARIA SDX DESEMBOCADURA DE SUCCI N SECUNDARIA SDX MDX PROFUNDIDAD DE 12 M NIMO PARA PREVENI...

Page 19: ...de la superficie del interior PRUEBA DE PRESI N DE MDX El estilo viejo de Tap n de Prueba 1 Aplique cuatro vueltas de cinta de Tefl n Inserte el tornillo en la tuerca Apriete con la llave o a mano has...

Page 20: ...ucci n Preparaci n de la capa de concreto Fig 2 Antes de instalar el terminado interior corte cada adaptador SDX aproximadamente 1 atras de la superficie de la capa de concreto Nota Los Standars de Se...

Page 21: ...eto 4 Forme un sello impermeable alrededor del tubo de succi n 5 Limpie el material que sobre y que quede en el Anillo de Concreto el la parte superior y en la superficie de monto Ensamble de la Cubie...

Page 22: ...elas y gu rdelas en el mismo lugar que los m dulos 2 Instale y asegure el tap n regular de preparaci n para el invierno en la l nea equalizadora de la canastilla a la alberca enseguida de la alberca 3...

Page 23: ...ya terminado 3 Use una mezcla para sellar que sea compatible con el interior de la superficie para sellar el anillo en su lugar y para obtener un sello que no entre el agua Ejemplo de la mezcla para s...

Page 24: ...ocadura 11 005 252 1611 00 Prueba de Presi n del Tap n 2 4 paquete 12 005 252 1605 00 Tap n 2 6 paquete 13 006 202 6180 00 Partes de Desembocadura que se requiere para reducir el tama o de la tuber a...

Reviews: