background image

21

INSTRUCCIONES PARA EL ACERO Y CEMENTO

CAPA DE CONCRETO

TIERRA

FUTURO SU

PERFICIE D

E INTERIOR

MEZCLA PARA SELLAR

ANILLO DE CONCRETO

KEY WAY

MDX Sistema de Recogida de Escombros

DISENO DE PISCINA/JACUZZI/CUENCO ESTANDAR

JAULA DE ACERO

ANILLO INTERIOR

3”

7” 8”

3 1/4”

3”

3”

6 1/8”

6”

6”

12”

CORONILLA DE TUBERÍA

10 1/8”

12”

Mantenga  la  varilla  a  3"  de  distancia  del  MDX  Sump.
Para  deharque  se  encubra  el  sump  limpie  la  tierra
completamente, para no exposar el codo.

1.

Compacte el cemento alrededor y abajo del sump

(Fig.  1)

para  asegurar  que  este  bien  sellado  y

reforzar la capa de concreto

2.

Directe la capa para bajo Hacia el MDX Sump. 

(Fig. 1)

3.

Haga un corte alrededor del MDX sump. 

(Fig. 2)

Instalación del Anillo de Concreto:

El  anillo  de  concreto  debe  ser  pegado  al  Paramount
Drain Sump antes de terminar el interior de la superficie
de la piscina, jacuzzi o cuenco.

1.

Alineé  la  abridura  del  anillo  con  la  abertura  de
alineación del Sump.

2.

Ajuste la elevación y el ángulo del anillo para que lo
alineé con la superficie interior del la piscina, jacuzzi
o cuenco ya terminado.

3.

Use una mezcla para sellar que sea compatible con
el interior de la superficie para sellar el anillo en su
lugar y para obtener un sello que no entre el agua.

*

Ejemplo de la mezcla para sellar: Mezcla de cemento
para  la  superficie,  cemento  hidráulico,  y  Thoro
Acryl®60 by ChemRex®

Ensamble el drenaje antes de agregar el agua 

(para referencia vea la ilustración en la página 20):

CAPA DE CONCRETO

TIERRA

FUTURO

 SUPERF

ICIE DE I

NTERIOR

CAPA DE CONCRETO

TIERRA

FUTURO SUP

ERFICIE DE I

NTERIOR

CORTE DE

ALREDEDOR

Fig. 1

Fig. 2

Fig. 3

1.

Instale las partes del embudo (No. 3) dentro del anillo
(No.  2)  apretando  el  adaptador  del  embudo  flexible
adentro  del  centro  del  tornillo  hembra  de  2½".
Presione  hacia  abajo  y  sostenga  las  partes  del
embudo para instalar los tornillos.

2.

Instale los dos (2) tornillos grandes (No. 5) en el soporte
(No. 8) con el desarmador de seguridad T25.

3.

Instale  los  dos  (2)  tornillos  medianos  (No.  6)  en  el
Ensamble del Embudo (No. 3), apriételos hasta que
el  Ensamble  del  Embudo  haga  contacto  con  la
superficie del interior de la piscina, jacuzzi o cuenco.
con el desarmador de seguridad T25.

4.

Coloque  la  cubierta  del  anti-torbellino  (No.  4)  en  el
Ensamble  del  Embudo  (No.  3)  e  instale  los  tres  (3)
tornillos chicos (No. 7) con desarmador de estrella.

Summary of Contents for MDX DEBRIS REMOVAL SYSTEM

Page 1: ...spa ol Page 11 MDX DEBRIS REMOVAL SYSTEM MANUAL MDX0804 004 027 8750 00 2 07 Notice to Installers Read and follow these instructions Give these instructions to the facility owner Follow all codes and...

Page 2: ...eading cause of Body Suction Entrapment Hazards Note your certified builder has many effective options for addressing this hazard they may include dual drain systems like MDX skimmers gutters negative...

Page 3: ...re it is not possible to exceed 90 GPM MDX DEBRIS REMOVAL SYSTEM INSTALLATION NOTICE 18 inches of 2 pipe is required to be connected to the center outlet of the MDX Debris Removal SystemTM After the 1...

Page 4: ...5 1 2 FT MAX 2 1 2 2 1 2 DEBRIS CANISTER SDX MDX VACUUM BREAKER VENT TO AIR 12 MINIMUM DEPTH TO AVOID AIR VORTEX LOWEST WATERLINE 5 FT MIN 5 1 2 FT MAX 2 1 2 2 2 1 2 DEBRIS CANISTER POOL SPA BASIN SDX...

Page 5: ...18 2 1 2 POOL WITH CANISTER WITHOUT CANISTER SDX 2nd SUCTION OUTLET SDX VACUUM BREAKER MDX 2 2 1 2 2 1 2 x 18 2 1 2 2 DEBRIS CANISTER SDX SDX VACUUM BREAKER MDX 2 1 2 2 1 2 x 18 2 1 2 2 12 MINIMUM DE...

Page 6: ...N OUTLET SDX 2nd SUCTION OUTLET MDX MDX DEBRIS CANISTER 2 2 1 2 x 18 2 1 2 x 18 2 1 2 2 1 2 2 1 2 SDX 2nd SUCTION OUTLET MDX SDX 2nd SUCTION OUTLET DEBRIS CANISTER MDX 2 1 2 2 1 2 x 18 2 1 2 x 18 2 1...

Page 7: ...of Teflon tape Insert plug into threaded socket Set plug wrench on lug and tighten by hand until snug Apply handle to wrench and turn 1 5 to 2 turns Do not under or over tighten plug OR USE ALTERNATE...

Page 8: ...ll Sump Fig 1 Form a concrete sump around each suction pipe Concrete Shell Preparation Fig 2 Prior to installing the interior finish cut each SDX riser pipe approximately 1 behind the concrete shell s...

Page 9: ...Ring 4 Form a watertight seal around the suction pipe 5 Wipe clean any finishing material that remains on the SDX Concrete Ring s top edge and mounting surface Concrete Cover Assembly Fig 4 1 Align th...

Page 10: ...the pool spa or basin 3 Use a sealing compound compatible with the interior surface to lock the Concrete Ring in place and to provide a water tight seal Sealing compound example Topping Mix Cement hyd...

Page 11: ...dditional questions should be forwarded to Paramount s corporate office at 1 800 621 5886 PARAMOUNT CANISTER WINTERIZATION TEST PLUGS 2 GALV SQ HEAD BALANCE LINE TO MAIN DRAIN TO OPTIONAL SKIMMER OR V...

Page 12: ...Head 12 pk 8 N A Support 9 005 202 1154 00 Plaster Cap 10 005 202 1148 00 Sump Construction Cap 11 005 252 1611 00 Plug Pressure Test 2 w O Ring 4 pk 12 005 252 1605 00 Plug 2 6 pk 13 006 202 6180 00...

Page 13: ...ANUAL PARA EL SISTEMA MDX DE RECOGIDA DE ESCOMBROS MDX0804 004 027 8750 00 2 07 Aviso a los instaladores Lea y siga estas instrucciones D le estas istrucciones al due o a Siga todos los c digos y regl...

Page 14: ...s comunes de Atrapamiento del Cuerpo AVISO su contratista certificado tiene muchas opciones efectivas acerca de este peligro pueden incluir sistemas de dos desag es como MDX espumaderas alcantarillas...

Page 15: ...por minuto LA INSTALACI N DEL SISTEMA MDX AVISO Se recomiendan 18 pulgadas de tuber a de 2 para conectarse al desag e de en medio del Sistema de MDX de eliminaci n de escombro Despu s de instalar 18 p...

Page 16: ...O CONTRA ROMPIMIENTO DEL EFECTO DE ASPIRACI N VENTILACI N AL AIRE PROFUNDIDAD DE 12 M NIMO PARA PREVENIR REMOLINO DE AIRE LINEA DE AGUA M S BAJA 5 FT MIN 5 1 2 FT MAX 2 1 2 2 2 1 2 CONTENEDOR DE ESCOM...

Page 17: ...SUCCI N SECUNDARIA SDX SEGURO CONTRA ROMPIMIENTO DEL EFECTO DE ASPIRACI N MDX 2 2 1 2 2 1 2 x 18 2 1 2 2 CONTENEDOR DE ESCOMBROS SDX SDX SEGURO CONTRA ROMPIMIENTO DEL EFECTO DE ASPIRACI N MDX 2 1 2 2...

Page 18: ...MDX CONTENEDOR DE ESCOMBROS MDX 2 1 2 2 1 2 x 18 2 1 2 x 18 2 1 2 2 1 2 2 SDX DESEMBOCADURA DE SUCCI N SECUNDARIA SDX DESEMBOCADURA DE SUCCI N SECUNDARIA SDX MDX PROFUNDIDAD DE 12 M NIMO PARA PREVENI...

Page 19: ...de la superficie del interior PRUEBA DE PRESI N DE MDX El estilo viejo de Tap n de Prueba 1 Aplique cuatro vueltas de cinta de Tefl n Inserte el tornillo en la tuerca Apriete con la llave o a mano has...

Page 20: ...ucci n Preparaci n de la capa de concreto Fig 2 Antes de instalar el terminado interior corte cada adaptador SDX aproximadamente 1 atras de la superficie de la capa de concreto Nota Los Standars de Se...

Page 21: ...eto 4 Forme un sello impermeable alrededor del tubo de succi n 5 Limpie el material que sobre y que quede en el Anillo de Concreto el la parte superior y en la superficie de monto Ensamble de la Cubie...

Page 22: ...elas y gu rdelas en el mismo lugar que los m dulos 2 Instale y asegure el tap n regular de preparaci n para el invierno en la l nea equalizadora de la canastilla a la alberca enseguida de la alberca 3...

Page 23: ...ya terminado 3 Use una mezcla para sellar que sea compatible con el interior de la superficie para sellar el anillo en su lugar y para obtener un sello que no entre el agua Ejemplo de la mezcla para s...

Page 24: ...ocadura 11 005 252 1611 00 Prueba de Presi n del Tap n 2 4 paquete 12 005 252 1605 00 Tap n 2 6 paquete 13 006 202 6180 00 Partes de Desembocadura que se requiere para reducir el tama o de la tuber a...