Pressure
125 psi [8.5 bar] ( STD 80 psi )
Speed
750 rpm (MAX)
Temperature
250°F [121°C] (MAX)
Flow Rate
125 gpm ( 1,000 SSU @ 750 rpm ) [473.2 lpm] (MAX)
Viscosity Capabilities
250,000 SSU [56,000 cP] (MAX)
Power Input Requirements
11.5 BHP [8.58 KW]
Maximum Pump Ratings
Mounting Considerations
• Mount the unit on a rigid, heavy base to provide support and absorb shock. The base
should be designed for rigidity across a flat even surface.
• Mounting kits are available with directional control valve mounting and ball valve
mounting. (Fig. 2)
• Positioning the product pump lower to the ground will assist with suction conditions and
decrease the risk of cavitation.
Initial Installation Considerations / Continued
Fig. 2
G125 w/ directional
control valve bracket
( pre-assembled,
RH rotation )
Over-pressure may burst
pump or system components.
Always include a relief valve
in installation. Do not over
pressurize pump or block
discharge line while running.