Paragon G Series Installation And Operation Manual Download Page 6

Note:   These are general guidelines and do not cover all possible situations. It is the responsibility 
of the system integrator to apply this product properly.  

Hydraulic Motor Orientation Considerations 

• The G125 is a hydraulic driven gear pump and is not 

intended for use with a driveline. (See pg 11 for hydraulic 
trunk specifications) 

• Hydraulic motor orientation must be checked prior to 

operation to ensure the correct pump rotation for the 
internal relief valve. (Fig. 1 & Fig. 3) 

• Refer to Manufacturer’s owners manual for specifications 

regarding the hydraulic motors.  Ensure the hydraulic relief 
valve setting does not exceed the hydraulic motor limitations. 

Hydraulic Hoses & Fitting Considerations 

DO NOT

 use thread tape or pipe dope on threaded connections, this will contaminate 

the hydraulic system. Use a hydraulic sealant (Locktite number 545 or similar) as 
required. 

• Hydraulic hoses are customer supplied, and will need to be measured to fit per 

application. Pre-plan hydraulic hose routing to minimize sharp bend radii, avoid surface 
contact, and to allow for flex during operation. 

• High pressure hoses must have a pressure rating equal or higher than the hydraulic 

system relief valve setting. 

• Hydraulic Hoses must be supported and not allowed to hang or pull on equipment 

 Piping Considerations 

• Inlet pipe should be as large in diameter, short in length, and straight as possible to 

minimize suction pressure losses. Excessive restrictions at the inlet can cause 
cavitation, resulting in poor performance, noise, vibration, or pump damage. 

• Slope the inlet plumbing appropriately to avoid air pockets.  

• Plumbing weight, misalignment with the ports, or thermal expansion can exert 

excessive force on the pump.  Plumbing must be properly supported and aligned with 
expansion joints, if required, to minimize these forces. 

• To prevent over pressure situations, install a relief valve as close to the pump outlet as 

possible. Install the relief valve before any shut-off valves. 

 

Initial Installation Considerations

 Fig. 1 

HP
 IN

Paragon  

302-009 & 302-010

rotation shown

Summary of Contents for G Series

Page 1: ...G125 Series Operation Manual August 07 2019 Installation and Operation Manual G Series Gear Pump Models G125...

Page 2: ...Congratulations on your new Paragon purchase...

Page 3: ...Safety Notice 3 Warning Labels 4 Initial Installation Considerations 5 6 Maximum Capabilities 6 Pre Operation Checks 7 Relief Valve Adjustment 8 Model Number Construction 9 Dimensions 10 Component Bre...

Page 4: ...are under the vehicle or working on any equipment Place any body part over any pneumatic or hydraulic leak or outlet while the equipment is in operation Engage or disengage driven equipment by hand f...

Page 5: ...reviewed by ALL operators Safety instruction tags were attached to your unit prior to shipment DO NOT remove paint over or obscure in any manner Failure to heed these warnings could result in serious...

Page 6: ...be measured to fit per application Pre plan hydraulic hose routing to minimize sharp bend radii avoid surface contact and to allow for flex during operation High pressure hoses must have a pressure ra...

Page 7: ...ld be designed for rigidity across a flat even surface Mounting kits are available with directional control valve mounting and ball valve mounting Fig 2 Positioning the product pump lower to the groun...

Page 8: ...for protected operation NOTE While in reverse operation the discharge circuit will be unprotected possible over pressurization can occur G125 relief valve is adjusted appropriately 100 psi from facto...

Page 9: ...re should NOT be set below or above the limits of the spring shown CAUTION DO NOT adjust the pressure rating or tamper with the chemical pump while it is in operation Setting the G125 Pump Relief Valv...

Page 10: ...F Elbow 3 Port CI X None G 2 Flange 2 Standard Bracket 3 Bracket w SCV DCV Single Port Oulet 4 Bracket w SCV DCV Two Port X None 5 Dual Spool One AUX B Elbow 2 NPT 6 Dual Spool Two AUX F Elbow 3 Port...

Page 11: ...haft with Key A B C D E F G H Model A B C D E F G H Port Size Approx Weight No Flanges Steel Shaft G 125 in 14 15 16 17 5 8 w Trunk 1 1 2 6 7 16 1 1 4 5 1 2 10 5 8 7 11 16 3 w o Flange 90 lbs mm 379 4...

Page 12: ...Component Breakdown 1 2 3 4 5 6 8 9 10 11 14 15 16 17 18 19 20 22 24 26 21 23 25 27 17 16 15 13 29 28 18 7 12...

Page 13: ...Relief Valve Spring 80 125 psi STD 1 22 580 013 Relief Valve Spring 20 80 psi 1 23 581 021 Relief Valve Spring Guide 1 24 581 022 Relief Valve Cap Gasket 1 25 581 023 Relief Valve Cap 1 26 581 024 RV...

Page 14: ...0 psi RV 581 016 Face Plate Assembly w Carbon Bushings 80 125 psi RV 581 017 Face Plate Assembly w Carbon Bushings 20 80 psi RV Replacement Pumps Standard pumps all LH Rotation 125 psi R V no flanges...

Page 15: ...riginal ex works point of shipment or refund an equitable portion of the purchase price The products and parts sold hereunder are not warranted for operation with erosive or corrosive materials or tho...