8786-A2-GB20-20
February 2001
7-1
7
Security
Overview
The termination unit provides several methods of security by limiting user access
to the ATI through option settings. You can:
Enable the Telnet Login Required option.
Limit the access by setting a Session Access Level option of Operator for the
Telnet Session.
Disable the access with the Telnet Session option.
See
Table A-5, Telnet Session Options,
in Appendix A,
Configuration Options
.
ATI Access Levels
The unit has two access levels: Administrator and Operator. The access level
determines what functions are accessible, as shown in
Table 7-1, Access Levels
.
Access level is also used to control access via Telnet. If the Telnet Session Access
Level is set to Administrator, a Login ID with an Operator access level is not
permitted access (see
Table A-5, Telnet Session Options,
in Appendix A,
Configuration Options
).
The effective access level is the more restrictive of the session access level or the
login access level.
Table 7-1.
Access Levels
ATI Access to Menu Functions
Administrator
Operator
Status
Read-Only
Read-Only
Test
Full Access
No Access
Configuration
Full Access
Read-Only
Control
Full Access
No Access
Summary of Contents for Hotwire 8786
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8786 A2 GB20 20...
Page 52: ...4 Monitoring the Unit 4 16 February 2001 8786 A2 GB20 20...
Page 62: ...5 Testing 5 10 February 2001 8786 A2 GB20 20...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8786 A2 GB20 20...
Page 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8786 A2 GB20 20...
Page 100: ...C Connector Pin Assignments C 2 February 2001 8786 A2 GB20 20...
Page 102: ...D Technical Specifications D 2 February 2001 8786 A2 GB20 20...