B. Standards Compliance for SNMP Traps
B-4
February
2001
8786-A2-GB20-20
There are no variable-bindings for enterpriseDeviceFail and
enterpriseConfigChange. The variable-binding for enterpriseSelfTestFail
is devSelfTestResults.
The following list describes the conditions that define enterpriseFallbackAutoRate
and enterpriseFallbackAutoRateClear:
enterpriseFallbackAutoRate Variable-Bindings
ifIndex (RFC 1573)
This object provides the index into the ifTable and potentially into tables in other MIBs.
The values of ifIndex are the same for all models, although not all indexes are
supported for each model.
The ifIndex included with the trap consists of the slot number times 1000, plus:
– 2DSL E1 Interface, Port 1
– 3DSL E1 Interface, Port 2
– 6G.703, Port 1
– 7G.703, Port 2
ifAdminStatus (RFC 1573)
This object specifies the operational state of the interface:
– up(1)
DSL Network: DSL link is established.
G.703: No alarm condition exists.
– down(2)
HDSL Network: DSL link is not established.
G.703: An alarm condition exists.
– testing(3)
A test is active on the interface.
ifOperStatus (RFC 1573)
This object contains the same value as ifAdminStatus.
i
fType (RFC 1573)
This object is the type of interface:
– e1(19)
Used for the G.703 E1 interface.
Summary of Contents for Hotwire 8786
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8786 A2 GB20 20...
Page 52: ...4 Monitoring the Unit 4 16 February 2001 8786 A2 GB20 20...
Page 62: ...5 Testing 5 10 February 2001 8786 A2 GB20 20...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8786 A2 GB20 20...
Page 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8786 A2 GB20 20...
Page 100: ...C Connector Pin Assignments C 2 February 2001 8786 A2 GB20 20...
Page 102: ...D Technical Specifications D 2 February 2001 8786 A2 GB20 20...