A. Configuration Options
8786-A2-GB20-20
February 2001
A-11
Table A-5.
Telnet Session Options
Telnet Session
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies if the unit will respond to a Telnet session request from a Telnet client on an
interconnected IP network.
Enable – Allows Telnet sessions between the unit and a Telnet client.
Disable – No Telnet sessions allowed.
Telnet Login Required
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies whether a user ID and password are required to access to the ATI through a
Telnet session. Login IDs are created with a password and access level. Refer to
Creating
a Login
in Chapter 7,
Security.
Enable – Security is enabled. When access is attempted via Telnet, the user is prompted
for a Login ID and password.
Disable – No Login required for a Telnet session.
Session Access Level
Possible Settings: Administrator, Operator
Default Setting: Administrator
The Telnet session access level is interrelated with the access level of the Login ID. Refer
to
ATI Access Levels
in Chapter 7,
Security, for more information.
Administrator – This is the higher access level, permitting full control of the unit. Access
level is determined by the Login ID. If Telnet Login Required is disabled, the session
access level is Administrator.
Operator – This is the lower access level, permitting read-only access to status and
configuration screens.
Inactivity Timeout
Possible Settings: Enable, Disable
Default Setting: Disable
Provides automatic logoff of a Telnet session.
Inactivity Timeout is not available if the unit is in a DSLAM running in
IP Conservative mode; this option is forced to Enable.
Enable – The Telnet session terminates automatically after the Disconnect Time.
Disable – A Telnet session will not be closed due to inactivity.
Summary of Contents for Hotwire 8786
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8786 A2 GB20 20...
Page 52: ...4 Monitoring the Unit 4 16 February 2001 8786 A2 GB20 20...
Page 62: ...5 Testing 5 10 February 2001 8786 A2 GB20 20...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8786 A2 GB20 20...
Page 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8786 A2 GB20 20...
Page 100: ...C Connector Pin Assignments C 2 February 2001 8786 A2 GB20 20...
Page 102: ...D Technical Specifications D 2 February 2001 8786 A2 GB20 20...