5. Testing
5-6
February 2001
8784-A2-GB20-30
Remote Send Line Loopback
The local unit initiates this test by sending a line loopback Up or Down command
to the remote unit for 10 seconds. When the remote unit detects the loopback Up
command, it puts itself in line loopback and lights the front panel Test LED. The
remote unit remains in loopback until it receives a loopback Down command or the
remote unit's test timeout value is exceeded.
The Send Line Loopback tests both units. External equipment can be used to
verify the link.
Procedure
To run a Remote Send Line loopback:
1. Position the cursor at the Up or Down selection next to Send Line Loopback on
the Network & DSX-1 Tests screen.
2. Press the spacebar to select either Up or Down.
3. Position the cursor at the Send command next to Up or Down selection.
4. Press Enter.
The local unit stops sending the loopback command automatically after
10 seconds. You cannot stop the Remote Send Line Loopback test manually.
The Remote Send Line Loopback cannot be started when any other loopback or a
Send and Monitor 511 test is active on the network interface.
CAP
DSX-1
Port
CAP
T1
LIU
Framer
Framer
Transceiver
98-16109
CAP
CAP
T1
LIU
Framer
Framer
Transceiver
AIS
Local
Remote
Summary of Contents for Hotwire 8784
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8784 A2 GB20 30...
Page 62: ...5 Testing 5 12 February 2001 8784 A2 GB20 30...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8784 A2 GB20 30...
Page 98: ...C Connector Pin Assignments C 2 February 2001 8784 A2 GB20 30...
Page 100: ...D Technical Specifications D 2 February 2001 8784 A2 GB20 30...