6
3A. Replace the Wall Jack with a Filter – NID Accessible
If the NID is not accessible, or the customer premises configuration is a 2-wire star,
proceed to
Replace the Wall Jack with a Filter – NID Not Accessible, or 2-Wire on
page 8.
Use the following procedure to install a SuperLine 6040 Wall Jack Filter when the NID is
accessible. When this procedure is complete, filtering is provided on Pins 3 and 4 and
SuperLine service is provided on Pins 2 and 5 of all wall jacks.
"
Procedure
1. Remove the existing wall jack and disconnect the wires from it. Note which wire
bundle runs to the NID and which one runs to the next wall jack.
2. If the wire ends are damaged, clip off the damaged portion. Strip the wires to
expose 1/4
I
of bare copper.
3. Remove the four screws from the faceplate of the filter and set aside the faceplate.
4. Connect the wires to the screw terminals on the filter assembly:
Screw Terminal On
Related
Customer Premises Wiring (If Present)
Screw Terminal On
Wall Jack Filter
Line Pin
Green or White/Blue from NID
FILTER IN – TIP
1
3
Red or Blue/White from NID
FILTER IN – RING
1
4
Green or White/Blue to next jack
FILTER OUT – TIP
1
3
Red or Blue/White to next jack
FILTER OUT – RING 1
4
Black or White/Orange both from NID and
to next jack
TIP 2
2
2
Yellow or Orange/White both from NID and
to next jack
RING 2
2
5
White or White/Green both from NID and to
next jack
TIP 3
3
1
Blue or Green/White both from NID and to
next jack
RING 3
3
6