Product-Related Documents
For information about the SuperLine IAD, refer to
SuperLine IAD, Models 6501, 6502,
6510, 6511, and 6512, Installation Instructions, Document Number 6500-A2-GN10.
To request a paper copy of a Paradyne document:
H
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
H
Outside the U.S.A., call 1-727-530-8623
Paradyne documents are also available on the World Wide Web at
www.paradyne.com. Select
Library
→
Technical Manuals.
Equipment Required
H
SuperLine 6040 Wall Jack Filter (one or more required)
H
Single-pair or multi-pair wire (if adding a new wall jack for the SuperLine IAD)
H
2-line splitter (if not adding a new wall jack for the SuperLine IAD)
Tools Required
H
Tone generator and probe, or power source and continuity tester
H
Phillips screwdriver
H
Flat-blade screwdriver
H
Wire cutter
H
Wire stripper
Installation Checklist
Installation of the SuperLine 6040 Wall Jack Filter consists of the following steps:
-
Disconnect the customer premises wiring from the local loop.
-
Determine whether wall jacks are wired in series or individually.
-
Replace wall jacks with SuperLine 6040 Wall Jack Filters as required.
-
Install new wiring (2-wire system) or a 2-line splitter (4-wire system) for the
SuperLine IAD.
-
If the customer premises has four wires, join the two pairs at the NID.
-
Reconnect the customer premises wiring to the local loop.
Procedures for each step are on the following pages.