TIP

RING

TIP 2

RING 2

TIP 3

RING 3

TIP

RING

FILTER IN

FILTER OUT

To NID

To Next
Jack
(If any)

99-16548

5. Fasten the filter assembly to the wall box using the screws that held the old wall

jack. An engraving on the filter assembly (UP

) shows the proper orientation.

6. Fasten the faceplate to the filter assembly.

If any other wall jacks are wired individually to the NID (see 

Determine Wiring

Arrangement on page 5), repeat the procedure for all wall jacks.

Summary of Contents for Hotwire 6040

Page 1: ...SuperLine Integrated Access Device IAD require a filter to isolate the voice frequency range from the SuperLine signal Basic Configurations 4 Wire Series The SuperLine 6040 Wall Jack Filter replaces t...

Page 2: ...ack Filter replaces all wall jacks in a 4 wire star configuration where each wall jack is wired individually to the NID 3 4 2 5 All Jacks Replaced with Filters NID 99 16546 3 4 2 5 3 4 2 5 Filter Inst...

Page 3: ...to the location of the SuperLine IAD in a 2 wire configuration NID 3 4 SuperLine 6040 Wall Jack Filter Filtered Unfiltered 99 16547 3 4 Standard Jack Added for SuperLine IAD New Wiring Added for Super...

Page 4: ...line splitter if not adding a new wall jack for the SuperLine IAD Tools Required H Tone generator and probe or power source and continuity tester H Phillips screwdriver H Flat blade screwdriver H Wir...

Page 5: ...ID or other entry point You must replace that wall jack with a Wall Jack Filter H If some or all wall jacks are wired in a star configuration that is more than one wall jack is wired directly to the N...

Page 6: ...ack 2 If the wire ends are damaged clip off the damaged portion Strip the wires to expose 1 4I of bare copper 3 Remove the four screws from the faceplate of the filter and set aside the faceplate 4 Co...

Page 7: ...ssembly to the wall box using the screws that held the old wall jack An engraving on the filter assembly UP shows the proper orientation 6 Fasten the faceplate to the filter assembly If any other wall...

Page 8: ...r and install the SuperLine IAD there If the SuperLine IAD must be installed elsewhere run new wiring to a standard wall jack from the FILTER IN TIP and RING connections of the filter to the new wall...

Page 9: ...UT RING 1 4 Black or White Orange to next jack FILTER IN TIP 2 2 Yellow or Orange White to next jack FILTER IN RING 2 5 White or White Green both from NID and to next jack TIP 3 3 1 Blue or Green Whit...

Page 10: ...point where the SuperLine IAD will be located 3 Install a standard wall jack and connect the new wiring to the Pin 3 and Pin 4 positions 4 Use the phone cord supplied with the SuperLine IAD to connec...

Page 11: ...the customer wants the SuperLine IAD installed 2 Plug a 2 line splitter into the wall jack at that location 3 Use the phone cord supplied with the SuperLine IAD to connect the LINE jack of the SuperLi...

Page 12: ...reen or white blue and the Tip wire of Line 2 black or white orange Join the Ring wire of Line 1 red or blue white and the Ring wire of Line 2 yellow or orange white Reconnect the line to the local lo...

Page 13: ...unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Avoid using a telephone other than a cordless type during an electric...

Page 14: ...subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Warranty Sales Service and Training Information Contact your S...