3B. Replace the Wall Jack with a Filter – NID Not Accessible, or 2-Wire
If the configuration is not 2-wire and the NID is accessible, go to
3A. Replace the Wall
Jack with a Filter – NID Accessible on page 6.
Use the following procedure to install a SuperLine 6040 Wall Jack Filter when the NID is
not accessible or the customer premises configuration is 2-wire. When this procedure is
complete, filtering is provided on Pins 3 and 4 and SuperLine service is provided on
Pins 2 and 5 of all wall jacks.
For a 2-wire series configuration, replace the wall jack nearest the NID with a Wall Jack
Filter and install the SuperLine IAD there. If the SuperLine IAD must be installed
elsewhere, run new wiring to a standard wall jack from the FILTER IN – TIP and RING
connections of the filter to the new wall jack.
"
Procedure
1. Locate the first wall jack connected to the NID.
2. Remove the existing wall jack and disconnect the wires from it. Note which wire
bundle runs to the NID and which one runs to the next wall jack.
3. If the wire ends are damaged, clip off the damaged portion. Strip the wires to
expose 1/4
I
of bare copper.
4. Remove the four screws from the faceplate of the filter and set aside the faceplate.
5. On the filter assembly:
— Remove the wire from TIP 2 and fasten it to FILTER IN – TIP
— Remove the wire from RING 2 and fasten it to FILTER IN – RING
TIP
RING
TIP 2
RING 2
FILTER IN