18
Setting Up the ISDN DBM
These instructions are for units with ISDN backup capability. The ISDN BRI DBM
supports up to 2 B-channels.
The following guidelines apply:
Central site
configuration guidelines:
—
Set up the ISDN DBM physical interface.
—
Change the Automatic Backup Configuration to Multi_Site_Backup. (A BRI
DBM is configured for Single_Site_Backup.)
—
Modify the Link Profile(s) that Automatic Backup Configuration created to add a
phone number.
Remote site
configuration guidelines:
—
Set up the ISDN DBM physical interface.
—
Modify the HQ_Site Link Profile that Automatic Backup Configuration created
to add a phone number.
—
Set the criteria by which automatic backup will take place.
Setting Up the DBM Physical Interface
Procedure
1.
Configure the DBM interface.
Main Menu
→
Configuration
→
ISDN
→
Physical
2.
Minimally, set the following configuration options:
—
Interface Status set to Enable.
—
Service Profile ID1 (SPID)
—
Local Phone Number 1
—
Service Profile ID2 (SPID)
—
Local Phone Number 2
3.
Save the configuration and return to the ISDN menu.