392xPlus S-Registers
S-Register
DCP LCD
Command
Sequence
Description
S52
DTE LL (CT141). Register determines if the modem performs a local analog
loopback if it receives a CT141 signal from the DTE.
Register has the following values:
0 = Disable
1 = Enable
2 = Fast
The factory setting is Disable.
Configure\Edit\
Tests
S53
V.54 Address. Identifies the address of the modem to be placed in a loopback
test.
Register has the following values:
0 = Disable
1–34 = Modem address
The factory setting is Disable.
Configure\Edit\
Tests
S54
V.54 Device Type. Identifies where the modem is physically located in the
network.
Register has the following values:
0 = Peripheral
1 = Intermediate
The factory setting is Peripheral.
Configure\Edit\
Tests
S55
Access from Remote. Register determines if a modem’s DCP can be
accessed by a remote modem.
Register has the following values:
0 = Enable
1 = Disable
The factory setting is Enable.
Configure\Edit\
Misc
S56
Remote Access Password. Register allows entry of the first pair (leftmost) of
digits of a remote access password. Any value from 00 to 99 is valid. For
example, if the remote access password is 12345678, then S56 = 1 and 2.
Configure\Edit\
Misc
S57
Remote Access Password. Register allows entry of the second pair of digits of
a remote access password. Any value from 00 to 99 is valid.
Configure\Edit\
Misc
S58
Remote Access Password. Register allows entry of the third pair of digits of a
remote access password. Any value from 00 to 99 is valid.
Configure\Edit\
Misc
S59
Remote Access Password. Register allows entry of the fourth pair (rightmost)
of digits of a remote access password. Any value from 00 to 99 is valid.
Configure\Edit\
Misc
S60
Callback Delay. Register determines the amount of time between disconnect
confirmation and callback initiation.
Register has the following values:
0 = Disable
1 = 20 seconds
2 = 40 seconds
3 = 1 minute
4 = 2 minutes
5 = 3 minutes
The factory setting is Disable.
Configure\Edit\
Misc
Summary of Contents for COMSPHERE 3920PLUS Series
Page 59: ...COMSPHERE 392xPlus Modems 3 18 October 1998 3920 A2 GH30 40 ...
Page 77: ...COMSPHERE 392xPlus Modems 4 18 October 1998 3920 A2 GH30 40 ...
Page 207: ...COMSPHERE 392xPlus Modems 11 4 October 1998 3920 A2 GH30 40 ...
Page 229: ...COMSPHERE 392xPlus Modems 12 22 October 1998 3920 A2 GH30 40 ...
Page 265: ...COMSPHERE 392xPlus Modems 14 32 October 1998 3920 A2 GH30 40 ...
Page 269: ...COMSPHERE 392xPlus Modems A 4 October 1998 3920 A2 GH30 40 ...
Page 289: ...COMSPHERE 392xPlus Modems D 8 October 1998 3920 A2 GH30 40 ...
Page 305: ...COMSPHERE 392xPlus Modems F 12 October 1998 3920 A2 GH30 40 ...
Page 327: ...COMSPHERE 392xPlus Modems G 22 October 1998 3920 A2 GH30 40 ...
Page 335: ...COMSPHERE 392xPlus Modems H 8 October 1998 3920 A2 GH30 40 ...
Page 337: ...COMSPHERE 392xPlus Modems I 2 October 1998 3920 A2 GH30 40 ...
Page 356: ... 3920 A2 GH30 40 3920 A2 GH30 40 ...