Configuration Options
4-10
9820-A2-GB20-20
June 2000
Setting Up Management
FrameSaver units are already set up for SNMP management, with Community
Name 1 set to Public and Name 1 Access set to Read/Write. For remote sites,
other than the IP Address, this is all that is required.
Configuration
→
Management and Communication
→
General SNMP Management
See Table 4-12,
General SNMP Management Options
, for configuration
information. For the central site, local management between the unit and the
router must be set up, as well (see
Setting Up Local Management at the Central
Site).
Setting Up Local Management at the Central Site
Set up a local management PVC between the central site unit and its router for
local management control by the end-user customer.
"
Procedure
To set up management through the router:
1. Create a DLCI that will be used for management on the user data port.
Configuration
→
Data Ports
→
DLCI Records
2. Create a Management PVC using the user data port DLCI just created.
Configuration
→
Management and Communication
→
Management PVC
Minimally, enter the following options:
— Name for the management PVC
— Interface IP Address and Subnet Mask, if different from the Node’s
— Primary Link for this Management PVC (the user data port)
— Primary DLCI (i.e., the data port DLCI)
3. Save the configuration.
See Table 4-8,
DLCI Record Options
, and Table 4-11,
Management PVC Options
,
for configuration information.
Summary of Contents for 9820
Page 10: ...Contents viii 9820 A2 GB20 20 June 2000...
Page 98: ...Configuration Options 4 62 9820 A2 GB20 20 June 2000 This page intentionally left blank...
Page 216: ...Menu Hierarchy A 4 9820 A2 GB20 20 June 2000 This page intentionally left blank...
Page 246: ...SNMP MIBs and Traps and RMON Alarm Defaults B 30 9820 A2 GB20 20 June 2000...
Page 266: ...Technical Specifications D 4 9820 A2 GB20 20 June 2000...
Page 270: ...Equipment List E 4 9820 A2 GB20 20 June 2000 This page intentionally left blank...