7. Operation and Maintenance
7-28
September
2002
9128-A2-GB20-80
Monitor
Pttn Active, Interface
2
A Monitor Pattern test is active on the specified
interface.
This test cannot be activated on user data ports that
have Port Use set to Frame Relay.
Network Initiated ISDN BRI Test
Active
An ISDN test has been started by the ISDN BRI
network and it is currently active.
Send
Pttn Active, DLCI nnnn,
frame_relay_link
1 ,3
A selected Send Pattern test is active on the
specified DLCI for the specified frame relay link.
Monitor
Pttn Active, DLCI nnnn,
frame_relay_link
1 ,3
A selected Monitor Pattern test is active on the
specified DLCI for the specified frame relay link.
Test Call Active,
ISDN Link Name
A test call is active on the specified frame relay link,
the link being the ISDN Link Name assigned in the
ISDN Link Profile.
This message would only appear for units with the
ISDN DBM feature.
Table 7-9.
Test Status Messages (2 of 2)
Message
What It Indicates
1
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n for a 1-slot unit, or SsPort-n for a NAM in a multislot housing (the frame relay
link associated with the specified user data port in the specified slot).
–
ISDN Link Name on a non-network ISDN DBM interface.
2
Interface is one of the following:
– Network 1
– DSX-1
– Port-
n
– ISDN, BRI or PRI
3
nnnn indicates a DLCI number of 16 through 1007.
Summary of Contents for 9126
Page 150: ...4 Configuration Options 4 106 September 2002 9128 A2 GB20 80 ...
Page 182: ...6 Security and Logins 6 16 September 2002 9128 A2 GB20 80 ...
Page 264: ...7 Operation and Maintenance 7 82 September 2002 9128 A2 GB20 80 ...
Page 348: ...A Menu Hierarchy A 4 September 2002 9128 A2 GB20 80 ...
Page 440: ...E Connectors Cables and Pin Assignments E 18 September 2002 9128 A2 GB20 80 ...