Messages and Troubleshooting
6-4
7110-A2-GB20-00
June 1997
Device Messages
The
Device Messages
in Table 6-1, listed in alphabetical order, may appear in the
messages area at the bottom of the ATI screens.
Table 6-1.
Device Messages (1 of 2)
Device Message
What Message Indicates
What To Do
Cannot Save – no
Login IDs with Access
Level 1
All of the login IDs being
saved have an access level
below Level 1.
Change the access level of at
least one Login ID to Level 1 so
that configuration changes can
be made. (Levels 2 and 3 cannot
make configuration changes.)
Save the Login IDs.
Command Complete
Action requested has
successfully completed.
No action needed.
Invalid Character (
x )
1
A nonprintable ASCII
character has been
entered.
Re-enter information using valid
characters.
Invalid – Data
Terminal (or Channel)
Initiated Loopback
Active
Network-initiated loopback
was in progress when
another selection was
made.
No action needed.
Invalid Password
Login is required and an
incorrect password was
entered; access is denied.
Try again.
Contact your system
administrator to verify your
password.
Invalid – [ Test ]
Already Active
The [test] was already in
progress when another
selection was made.
Allow test to continue.
Select another test.
Stop the test.
Invalid Test
Combination
A loopback or pattern test
was in progress when Start
was selected to start
another test, or was active
on the same or another
interface when Start was
selected.
Wait until other test ends and
message clears.
Abort all tests from the Test
menu screen.
Stop the test from the same
screen the test was started
from.
Limit of six Login IDs
reached
An attempt to enter a new
login ID was made, and the
limit of six login/password
combinations has been
reached.
1. Delete another login/password
combination.
2. Re-enter the new login ID.
No Security Records
to Delete
Delete was selected from
the Administer Login
screen, and no security
records had been defined.
No action needed.
Enter a security record.
1
x is the character not being accepted.