background image

Summary of Contents for 6512-A2

Page 1: ...GN10 40 June 1999 TST LINE ALM PWR ETHERNET TM TM 98 16014a 02 BASE PHONE Rear View Front View SuperLineTM IAD Contents Introduction 2 Installation 5 Troubleshooting 24 Front Panel Indicator Lights 26 Technical Information 28 Additional Notes on SuperLine IAD Operation 32 Important Safety Instructions 33 ...

Page 2: ...al phones fax machines or modems simultaneously H Provides high speed Internet access through an Ethernet connection Available in some areas Ask your service provider about availability of this service H Operates with Touch Tonet phones The PHONE 1 2 and PHONE 2 jacks do not support pulse dial phones Your existing phone plugged into the BASE PHONE jack can be a pulse dial phone The following figur...

Page 3: ... 002 TST LINE ALM PWR ETHERNET TM TM L I N E P H O N E gepruf te Sicher heit R LR 92997 TM T U Y PR OD UC T SE RV I C E P h o n e F i l t e r P N 0802 3392 00 Made in China Fabriquè China Bel Fu se Inc 1198 AC CESSARY L T E EQUIPMENT E100296 99 16406 LIN E P H O N E 99 16410 geprufte Sicherheit R LR9299 7 TM TUY PRODUCT SERVICE Phon e Filter P N 0802 339 2 00 Made i n China Fabriq uè China Bel Fus...

Page 4: ...4 ...

Page 5: ...t Phone Filters to Your Existing Phones Page 14 This procedure describes how to connect a phone filter to your existing phones H Connect a 2 Line Phone to the Existing and Additional Phone Line Page 16 This procedure describes how to connect a 2 line 2 cord phone to your SuperLine IAD H Connect a 2 Line Phone to Two Additional Phone Lines Page 18 This procedure describes how to connect a 2 line 1 ...

Page 6: ...he cable into the wall jack Add a Second Phone Line Connect a phone to the PHONE 1 2 jack on the SuperLine IAD rear panel Connect the Existing Phone Line If you wish to have your existing phone line available in this location connect your existing phone to the BASE PHONE jack on the SuperLine IAD rear panel Connect the ac power transformer Insert the power cord s cylindrical plug into the jack lab...

Page 7: ...7 Additional Phone Phone 1 2 Base Phone Line Wall Jack Existing Phone 99 16430 Power Adding a Second Line for a Phone ...

Page 8: ...d of the cable into the wall jack Connect the Modem Connect the output of your modem to the PHONE 1 2 jack on the SuperLine IAD rear panel Connect the Existing Phone Line If you wish to have your existing phone line available in this location connect your existing phone to the BASE PHONE jack on the SuperLine IAD rear panel Connect the AC Power Transformer Insert the power cord s cylindrical plug ...

Page 9: ...9 99 16066 03 Phone 1 2 Base Phone Wall Jack Line Existing Phone Fax Data Modem Power Adding a Second Line for a Modem ...

Page 10: ...of the supplied phone cable into the LINE jack on the SuperLine IAD rear panel Plug the other end of the cable into the wall jack Connect the Modem Connect the output of your modem to the PHONE 1 2 jack on the SuperLine IAD rear panel Connect the Additional Phone Connect a phone to the PHONE 2 jack on the SuperLine IAD rear panel Connect the Existing Phone Line º If you wish to have your existing ...

Page 11: ...ting phones Refer to Connect Phone Filters to Your Existing Phones on page 14 Your SuperLine IAD installation is now complete 99 16434 Phone 1 2 Base Phone Wall Jack Line Existing Phone Fax Data Modem Phone 2 Additional Phone Power Connecting a Modem and an Additional Phone ...

Page 12: ...AD Plug one end of the supplied phone cable into the LINE jack on the SuperLine IAD rear panel Plug the other end of the cable into the wall jack Connect to High Speed Data Service Connect the network interface card of your PC to the ETHERNET jack on the SuperLine IAD rear panel with a crossover cable If you are connecting to a hub you need a straight through Ethernet cable See High Speed Data Ser...

Page 13: ...e Installation Attach phone filters to all your other existing phones Refer to Connect Phone Filters to Your Existing Phones on page 14 Your SuperLine IAD installation is now complete Fax Machine Phone 2 Phone 1 2 Base Phone Line 99 16433 Ethernet Existing Phone PC with Network Interface Card Additional Phone Wall Jack Power Adding High Speed Data Service a Fax Machine and an Additional Phone ...

Page 14: ...ired Not Supplied You may need to obtain additional phone filters from your service provider One filter is supplied with your SuperLine IAD Procedure Use the following procedure to install phone filters on your existing phones Disconnect the phone cord of your existing phone from the wall jack Plug the phone cord into the PHONE jack on the phone filter Plug the phone filter into the wall jack Repe...

Page 15: ...iche rheit R L R 9 2 9 9 7 TM TUY PRO DUC T SER VIC E Phone Filter P N 0 8 0 2 3 3 9 2 0 0 M a d e i n C h i n a F a b r i q u è C h i n a B e l F u s e In c 1 1 9 8 A C C E S S A R Y L T E E Q U IP M E N T E 1 0 0 2 9 6 Installing a Phone Filter ...

Page 16: ...not provided with other equipment you have bought H Existing phone cables Procedure Connect the SuperLine IAD Plug one end of the supplied phone cable into the LINE jack on the SuperLine IAD rear panel Plug the other end of the cable into the wall jack Connect Line 1 Connect Line 1 of your 2 line phone to the BASE PHONE jack on the SuperLine IAD rear panel Connect Line 2 Connect Line 2 of the 2 li...

Page 17: ...existing phones Refer to Connect Phone Filters to Your Existing Phones on page 14 Your SuperLine IAD installation is now complete 99 16100 03 Phone 1 2 Base Phone Line 2 Line 1 2 Line Phone Wall Jack Line Power Connecting a 2 Line Phone with One or Two Additional Lines ...

Page 18: ...n on page 23 for more information Procedure Connect the SuperLine IAD Plug one end of the supplied phone cable into the LINE jack on the SuperLine IAD rear panel Plug the other end of the cable into the wall jack Connect Lines 1 and 2 Connect your 2 line phone using your 2 line RJ14C phone cable to the PHONE 1 2 jack on the SuperLine IAD rear panel The 2 line phone cable connects both lines throug...

Page 19: ...19 99 16036a 03 Phone 1 2 RJ14 Phone Cable 2 Line Phone Wall Jack Line Phone 2 not used in this configuration Connecting a 2 Line Phone to Two Additional Lines ...

Page 20: ...ine IAD with multiple phones fax machines or modems connected in other rooms Connect the SuperLine IAD Plug a T type connector into the wall jack of the room where the SuperLine IAD is located Plug one end of the supplied phone cable into the LINE jack on the SuperLine IAD rear panel Plug the other end of the cable into Line 1 of the T type connector Plug a phone cable into Line 2 of the T type co...

Page 21: ... 2 4 Wire Internal Wiring Line 2 Line 1 Line Phone Filter Existing Phone Line Line 1 Line 2 Phone Filter Existing Phone Line Line 1 Additional Line Additional Line Additional Line PHONE LINE PHONE LINE T T T T T Type Connector Wall Jack Not all homes or offices are wired internally with 4 wires If you are unsure of your internal home or office wiring contact your service provider or an electrician...

Page 22: ...our SuperLine IAD to a PC or hub Connect the SuperLine IAD Plug one end of the supplied phone cable into the LINE jack on the SuperLine IAD rear panel Plug the other end of the cable into the wall jack Connect to High Speed Data Servce Plug one end of the cable into the ETHERNET jack on the SuperLine IAD rear panel Use an 8 pin Ethernet crossover cable to connect your PC Use an 8 pin straight thro...

Page 23: ...all your existing phones Refer to Connect Phone Filters to Your Existing Phones on page 14 Your SuperLine IAD installation is now complete 99 16038a 02 or Wall Jack Ethernet PC Hub TST LINE ALM PWR ETHERNET Power Line Connecting to High Speed Data Service ...

Page 24: ...e of your SuperLine IAD This operation may be performed periodically to ensure your SuperLine IAD operates to its full potential The condition normally lasts only a few minutes During this time your existing BASE phone continues to operate but your additional lines are not available If this condition persists for more than 10 minutes unplug the power cord and plug it back in If the problem continu...

Page 25: ...e calls Verify the total Ringer Equivalency Number REN of all of the devices connected to your PHONE 1 2 or PHONE 2 jack does not exceed 3 REN is normally specified on a label on the phone fax machine or modem The PHONE 2 jack has no dial tone Verify that your service provider has supplied you with two additional lines You detect distortion on the phone connected to the PHONE 1 2 or PHONE 2 jack o...

Page 26: ...N during the power on self test and during testing or upgrades initiated by your service provider Additional lines are not available when the TST indicator is ON Your existing BASE phone still works LINE ON OFF Your SuperLine IAD is connected to your local phone company and is ready to use The link has not been established ETHERNET ON OFF The Ethernet connection to your PC or Ethernet Hub is made ...

Page 27: ...ur SuperLine IAD PHONE 1 2 Connect a phone fax machine or modem if you have one or two additional lines This jack is also used to connect a 2 line phone with a single 2 line phone cable if you have ordered two additional lines ETHERNET Connect high speed Ethernet data services Ask your service provider about the availability of high speed Ethernet data services BASE PHONE Connect your existing pho...

Page 28: ...ters are required to minimize audible background noise that occurs with your existing telephones during phone conversations on phones not connected through your SuperLine IAD RJ11 or RJ14C Phone Cables H All standard phones fax machines and modems that connect to your SuperLine IAD use a 6 pin non keyed modular plug RJ11 or RJ14C RJ11 6 Pin RJ14C 6 Pin Connector Connector Pin Function Pin Function...

Page 29: ...n 1 10BaseT TX D 2 10BaseT TX D 3 10BaseT RX D 4 5 Not used 6 10BaseT RX D 7 8 Not used H Use an Ethernet crossover cable to connect your SuperLine IAD directly to a PC with an Ethernet network interface card 24 AWG Cat 5 cable is recommended 10BaseT TX D 10BaseT TX D 10BaseT RX D Not Used Not Used 10BaseT RX D Not Used Not Used 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 10BaseT TX D 10BaseT TX D 10BaseT RX ...

Page 30: ...crosses the normally unused Pins 2 and 5 to Pins 3 and 4 on Line 2 of the SuperLine IAD Connecting your SuperLine IAD to Line 2 on the T connector creates an electrical connection to any room with a wall jack by using a second T connector and connecting the phone in that room to Line 2 of the second T connector Do not use a T type connector to connect two SuperLine IADs to a single wall jack 1 2 3...

Page 31: ... 6 5 w 22 2 Btu hr maximum at nominal input voltage Interface Connectors Line and Phone Interfaces Ethernet Type II Frame RJ11 RJ14C 6 pin 10BaseT 8 pin REN Support Provides adequate ringing signals for a total REN of 3 on each SuperLine port PHONE 1 2 or PHONE 2 The BASE phone REN load is labeled on the equipment See page 34 Technical Specifications subject to change without notification Technica...

Page 32: ...r optimal performance do not use the BASE PHONE jack to connect a modem The Phone 2 jack does not work if you have ordered only one additional phone line Use the Phone 1 2 and Base Phone jacks If you use the PHONE 2 jack do not use a 4 wire phone cable to connect phones fax machines or modems to the PHONE 1 2 jack A 4 wire phone cable connected to the PHONE 1 2 jack may cause interference on phone...

Page 33: ...ocations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning Do not use the telephone to report a gas leak in the vicinity of the...

Page 34: ...revent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request to disconnect the equipment Users should ensure for their own protection that the electrical ground connec...

Page 35: ......

Page 36: ... 6512 A2 GN10 40 ...