SNMP-NET 

 

4

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 1-1 System Application Diagram   

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 

Figure 1-2 SNMP-NET Card

 

 
 
 
 
 

UPS 

SNMP-NET 

SNMP Card

NMS Station or 

Web Browser 

Shutdown S/W  

Shutdown S/W 

Shutdown S/W 

Operating 

System 1 

Power Line 

Ethernet 

Operating 

System 2 

Operating 

System N. 

Ethernet Connection 

Reset Button

Console / ENV Connection

Dip Switches

Summary of Contents for Minuteman SNMP-NET

Page 1: ...PN 34000281 R1 SNMP NET UPS SNMP Card Web Based monitoring SNMP Card User s Manual...

Page 2: ...e and Exit 11 Chapter 4 Managing SNMP NET 12 Running the Web Browser Internet Explorer 12 Smart Shutdown 12 External Battery Pack 12 UPS Shutdown Schedule 12 UPS Shutdown during Power Crisis 13 Wake C...

Page 3: ...utdown The shutdown software included provides an automatic shutdown either pre programmed by administrator or when critical power events occur Notification of users via SNMP Traps and e mail through...

Page 4: ...e 1 2 SNMP NET Card UPS SNMP NET SNMP Card NMS Station or Web Browser Shutdown S W Shutdown S W Shutdown S W Operating System 1 Power Line Ethernet Operating System 2 Operating System N Ethernet Conne...

Page 5: ...T device If there is no DNS server then you need to assign an IP address for the mail server if you want to be notified e mail 11 We recommended disabling the BOOTP DHCP option and assign a valid stat...

Page 6: ...SNMP NET EzSetting program then launch it 5 Press the Discover button to search for all of the UPS in the LAN All of the UPS SNMP DEVICE will be listed in the Device List See 2 1 Figure 2 1 EzSetting...

Page 7: ...ion running Microsoft Windows 9x Me NT4 0 2000 2003 XP or later click on the HyperTerminal icon of the accessory programs group 5 Enter a name and choose an icon for the connection 6 Select direct COM...

Page 8: ...yed on the screen Key in the administrator account default account is admin and password default password is password The SNMP NET configuration main menu will be displayed on the screen Please refer...

Page 9: ...ttings password 3 Device Account device 4 Device Password Device Manager is permitted to change the network setting but has the ability to configure the UPS settings password 5 User Account user 6 Use...

Page 10: ...NET access you can use the access table to add the IP address of the PC s on which you wish to modify the access permissions Figure 2 7 The communication protocol between the shutdown software SNMP N...

Page 11: ...000 None 6 000 000 000 000 None 7 000 000 000 000 None 8 000 000 000 000 None 0 Back To Previous Menu Please Enter Your Choice Figure 2 8 SNMP Trap Time Server There are 2 ways to provide the current...

Page 12: ...00 0 Back To Previous Menu Please Enter Your Choice Figure 2 10 Setting Trap Receivers Upgrade Firmware SNMP NET supports TFTP Client protocol for upgrading the firmware version You need a TFTP server...

Page 13: ...process When shutdown software receives the Smart Shutdown signal the low battery reaction settings will be used to process the shutdown procedure External Battery Pack If you are using an External B...

Page 14: ...his feature is only available for the servers in the same LAN with SNMP NET device Email Notification This page is to setup the email notification settings to receive a notification or a report from S...

Page 15: ...The power fail simulate will be terminated automatically in 30 minutes Updating SNMP NET Firmware from Windows To perform firmware upgrade use the EzSetting exe program on the CD ROM 1 Device List Dis...

Page 16: ...ty string which has been set in the SNMP Access Control menu The SNMP NET Client service connects to the device automatically when the operating system initiates Note When the SNMP NET Client connects...

Page 17: ...nsumption 1 Watt Maximum Size 130 mm x 60 mm L x W Weight 58 g Dipswitch Definition No SW1 SW2 Function Mode 1 ON ON Console Configuration Mode 2 ON OFF For Environmental Sensor 3 OFF ON Pass Through...

Page 18: ...the IP address and MAC address from my computer Solution In the Windows system type in ipconfig all at the DOS prompt For Unix system use ifconfig in the shell 5 Unable to ping or connect to the SNMP...

Page 19: ...l NMS IP fields with Read Write permission The Community String on the PC and UPS Adapter must match 8 Unable to receive traps at your management station Solution Check the SNMP Trap settings in the S...

Page 20: ...ateway running SNMP NMS Network Management Station A combination of hardware and software used to monitor and administer a network OID Object Identifier The variables defined in a MIB Router A device...

Page 21: ...you Installation Site Company Name Address City State ZIP code Contact Person s Name Phone Number If you are a consultant Consultant Name Phone Number Fax Number Computer System Operating System and v...

Page 22: ...duct s operating manual or other written instructions Any technical advice furnished before or after delivery in regard to use or application of Para Systems s equipment is furnished without charge an...