BA_PH_245-100-300_EN_06-22.docx
43
14.2.3.2
Battery Change
Figure 34: Handwheel battery change
(
1
) Screws
(
2
) Battery unit
(
3
) O-ring
(
4
) Housing
Please note:
Improper assembly leads to loss of protection class.
•
Tighten screws (
1
) evenly until the battery unit
(
2
) is completely at the stop with the housing (
4
).
•
Check the correct position of the O-ring (
3
).
14.2.3.2.1
Preparation:
1.
Switch on the main switch of the machine, so that the indicator is active.
2.
Have the replacement battery unit ready. The battery unit is available on the
manufacturer’s website at
3.
Prepare Phillips screwdriver (e.g. PH 0x60).
14.2.3.2.2
Disassembly
:
1.
The battery compartment is located on the left side of the unit (connections at the bottom).
2.
Unscrew the three fixing screws (
1
).
3.
Remove the battery unit (
2
) (disposal of the old battery).
Fire, explosion and burn hazard! Never recharge the batteries used in the AP 10 or expose
them to temperatures above 85° C.
Used batteries must not get into fire, water or groundwater and must not be disposed of in
household waste. Collect batteries and dispose of them in an environmentally friendly manner
(e.g. at an official collection point for batteries).
14.2.3.2.3
Mounting
:
4.
Install the new battery unit (
2
). Ensure easy joining.
5.
Check the correct position of the O-ring (
3
). The O-ring (
3
) must be in circumferential
contact with the battery housing during installation of the battery unit (
2
).
14.2.3.3
Additional Documents
The original operating manual AP-10 can be found under the following link:
www.siko-global.com/adbimage/25428/asset_original/installation-instructions-ap10.pdf
Further information and documents on the AP-10 can be found on the manufacturer's website: