BA_PH_245-100-300_EN_06-22.docx
36
13
Speed Setting
13.1
Version 245|100
With the 245|100 version, the speed is adjusted by shifting the V-belt.
Switch off the machine during speed adjustment and secure it against unexpected restarting.
Lock the main switch with a padlock!
After switching off and locking the main switch, open the front service door and proceed as follows:
Figure 22: Lever to release the V-belt
•
Swivel lever (
E
) according to
•
Set the loosened belt to the desired speed:
•
To tension, swing lever (
E
) back again.
•
After the adjustment, set the brake release switch back to the right-hand position (normal operation).
Please also read the chapter
18.6 “Change and Tighten the Drive Belt”.
13.2
Versions 245|200 and 245|300
These models have a frequency inverter that allows infinitely variable speed regulation from 1,500 to 10,000
rpm. The speed is adjusted via the touchscreen control:
•
See chapter "Speed Settings" in the separate operating manual
BA_PH_UT300_EN
Danger of electric shock on the frequency inverter! Wait at least 15 minutes after switching
off the main switch before working on the frequency inverter.
13.3
Cutting Speed Chart
Figure 23: Cutting Speed Chart
There is a cutting speed chart on the right-hand side
of the machine.
•
Select the speed for the cutter used according to
the chart and be sure to avoid settings within the
danger zones marked in yellow and red.
Increased risk of kickback, breakage
and/or noise pollution when choosing a
non-recommended setting!
E
Motor
6000 rpm
9000 rpm
3000 rpm
4500 rpm
Risk of breakage,
increased noise pollution
Increased
risk of kickback
To
ol
d
ia
me
te
r (
m
m)
Milling arbor speed (
min
-1
)