TECHNICAL SPECIFICATIONS -
Air Supply
ITEM
DESCRIPTION
Recommended regulated air pressure supplied to tool
(pressures other than recommended may result in
unsatisfactory operation):
Regulator settings: 75 PSIG (5,2 bar) with a max. 10 PSI
(0,7 bar) drop.
MAXIMUM 90 PSIG
(6,2 bar).
Air consumption at 30 cycles per minute:
.091 cfm @ 75 PSIG (0,043 l/sec @ 5,2 bar)
Line pressure supplied to regulator:
Minimum 70 PSIG (4,8 bar),
Maximum 90 PSIG (6,2 bar)
Filter/regulator requirements:
5 micron maximum element rating, 5 PSI (0,3 bar) maximum
pressure drop @ 70 PSIG (4,8 bar) inlet pressure and 12
cfm (5,7 l/sec) flow minimum.
Lubrication for air supply:
Air line lubricators are NOT to be used.
Recommended filter/regulator unit (supplied by user) with
1/8” NPT ports and 1/4” quick disconnect (industrial
interchange) plug:
Recommended source: Panduit Part Number PL289N1
EU Panduit Part Number: MK-06
Recommended main air supply hose (10 ft.), (supplied by
user) from filter/regulator to tool (supplied by user); includes
a 1/8” NPT male connector (to regulator) and a 1/8” quick
disconnect socket (to tool):
Recommended source: Panduit Part Number PPH10
EU Panduit Part Number:
PPH10G
DAILY TOOL INSPECTION
1. Visually inspect nose area for foreign matter and cable tie scrap. Keep this area clear of foreign matter.
2. Visually inspect applied cable ties for correct tension and cut-off to verify the working condition of the blade and gripper.
© Panduit Corp. 2016
OPERATION INSTRUCTIONS
PTS-EN
OPERATION
1. Reading the tension knob from the top of the tool, rotate the
knob to select the cross section of cable ties to be installed.
MIN – M: Approx. 0.098" (2.5mm) wide cable ties
(Submin: Approx. 0.070" (1.8mm) wide cable ties)
INT – I: Approx. 0.142" (3.6mm) wide cable ties
STD – S: Approx. 0.190" (4.8mm) wide cable ties
If necessary, further adjust tension per Tension Adjustment
instructions below.
2. Loop cable tie around bundle and insert the tip through the
head. Pull the tie up snug on the bundle by hand.
3. Insert the strap of the cable tie into the side of the tool. With the
nose of the tool flush to the cable tie head, squeeze the
trigger to tighten the cable tie. Typically, only one depression of
trigger is necessary for cable tie cut-off.
Fine Adjustment Knob
TENSION ADJUSTMENT
There is a tension indicator on the top of the tool. The tension
setting can be changed by turning the fine adjustment knob:
0-3 for MIN; 3-5 for INT; and 6-8 for STD
(0-1 for Subminiature ties)
PTS Replacement Kits and Accessories Available • Contact Panduit for more information
KGTSBLD
Blade Replacement Kit - For replacement of a worn blade
KPTSTL
Tool Tension Locking Kit - May be installed to prevent adjustment of the tension knob
PHCAQ
Adapter Fitting for Hose (PPH10) - 1/4" Male Quick Disconnect (to regulator).
PHCAT
Adapter Fitting for Hose (PPH10) - 1/4" NPT Male Connection (to regulator).
WB24468D01
Blade Guard Housing - For replacement of a worn blade guard